Skip to main content

Ozw672 Firmware CVE-2024-36140

HIGH
Cross-site Scripting (XSS) (CWE-79)
2024-11-12 productcert@siemens.com
8.2
CVSS 4.0 · Vendor: siemens
Share

Severity by source

Vendor (siemens) PRIMARY
8.2 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
P
Scope
X

Lifecycle Timeline

1
CVE Published
Nov 12, 2024 - 13:15 cve.org
HIGH 8.2

DescriptionCVE.org

A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks.

This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker.

AnalysisAI

A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks. This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker. Affected products include: Siemens Ozw672 Firmware, Siemens Ozw772 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

Share

CVE-2024-36140 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy