Skip to main content

Ac10U Firmware CVE-2024-2853

CRITICAL
OS Command Injection (CWE-78)
2024-03-24 cna@vuldb.com
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Mar 24, 2024 - 05:15 nvd
CRITICAL 9.8

DescriptionNVD

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac10U Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

CVE-2024-0932 CRITICAL POC
9.8 Jan 26

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical

CVE-2024-0931 CRITICAL POC
9.8 Jan 26

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9

CVE-2024-0930 CRITICAL POC
9.8 Jan 26

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (C

CVE-2024-0929 CRITICAL POC
9.8 Jan 26

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability

CVE-2024-0928 CRITICAL POC
9.8 Jan 26

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability

CVE-2024-0927 CRITICAL POC
9.8 Jan 26

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9.8), this vulnerability

CVE-2024-0926 CRITICAL POC
9.8 Jan 26

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severity (CV

CVE-2024-0925 CRITICAL POC
9.8 Jan 26

A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. Rated critical severit

CVE-2024-0924 CRITICAL POC
9.8 Jan 26

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical seve

CVE-2024-0923 CRITICAL POC
9.8 Jan 26

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical

CVE-2024-0922 CRITICAL POC
9.8 Jan 26

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Rated critical severity (CVSS 9

CVE-2024-2764 HIGH POC
8.8 Mar 21

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. Rated high severity (CVSS 8.8),

Share

CVE-2024-2853 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy