Cross-Site Request Forgery (CSRF) (CWE-352)
2024-03-08 cna@vuldb.com
4.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.3 MEDIUM
AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
None
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Mar 08, 2024 - 12:15 nvd
MEDIUM 4.3

DescriptionNVD

A vulnerability has been found in Bdtask Hospital AutoManager up to 20240227 and classified as problematic. This vulnerability affects unknown code of the file /billing/bill/edit/ of the component Update Bill Page. The manipulation leads to cross-site request forgery. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256270 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability has been found in Bdtask Hospital AutoManager up to 20240227 and classified as problematic. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Request Forgery (CSRF) (CWE-352), which allows attackers to trick authenticated users into performing unintended actions. A vulnerability has been found in Bdtask Hospital AutoManager up to 20240227 and classified as problematic. This vulnerability affects unknown code of the file /billing/bill/edit/ of the component Update Bill Page. The manipulation leads to cross-site request forgery. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256270 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Bdtask Hospital Automanager. Version information: up to 20240227.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement anti-CSRF tokens, validate Origin/Referer headers, use SameSite cookie attribute.