Skip to main content

Firepower Management Center CVE-2024-20388

MEDIUM
Exposure of Sensitive Information Through Data Queries (CWE-202)
2024-10-23 psirt@cisco.com
5.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
5.3 MEDIUM
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Oct 23, 2024 - 18:15 nvd
MEDIUM 5.3

DescriptionNVD

A vulnerability in the password change feature of Cisco Firepower Management Center (FMC) software could allow an unauthenticated, remote attacker to determine valid user names on an affected device. This vulnerability is due to improper authentication of password update responses. An attacker could exploit this vulnerability by forcing a password reset on an affected device. A successful exploit could allow the attacker to determine valid user names in the unauthenticated response to a forced password reset.

AnalysisAI

A vulnerability in the password change feature of Cisco Firepower Management Center (FMC) software could allow an unauthenticated, remote attacker to determine valid user names on an affected device. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-202. A vulnerability in the password change feature of Cisco Firepower Management Center (FMC) software could allow an unauthenticated, remote attacker to determine valid user names on an affected device. This vulnerability is due to improper authentication of password update responses. An attacker could exploit this vulnerability by forcing a password reset on an affected device. A successful exploit could allow the attacker to determine valid user names in the unauthenticated response to a forced password reset. Affected products include: Cisco Firepower Management Center, Cisco Secure Firewall Management Center, Cisco Firepower Threat Defense.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2024-20388 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy