Skip to main content

Ac6 Firmware CVE-2024-10697

MEDIUM
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2024-11-02 cna@vuldb.com
5.3
CVSS 4.0 · Vendor: vuldb
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Input neutralization, injection prevention
Impact

CVSS score of 5.3 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the medium-severity affected system.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 25.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-74. A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Affected products include: Tenda Ac6 Firmware.

Know when Ac6 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (vuldb) PRIMARY 5.3 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N

Primary rating from Vendor (vuldb) · only source for this CVE.

CVSS VectorVendor: vuldb

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
Low
Vulnerable system: Availability
Low
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Threat Intelligence Overview

EPSS Score
25.5%
Top 2% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC Yes
EPSS 25.5%
Patch available No
Active threat Yes
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

72
Low Medium High Critical
KEV: 0
EPSS: +26
CVSS: +26
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:ac6_firmware:15.03.05.19:*:*:*:*:*:*:*
CVE-2024-52714 CRITICAL POC
9.8 Nov 19

Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. Rated critical

CVE-2025-25343 CRITICAL POC
9.8 Feb 12

Tenda AC6 V15.03.05.16 firmware has a buffer overflow vulnerability in the formexeCommand function. Rated critical sever

CVE-2025-29031 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function. Rated critical sever

CVE-2025-29030 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated critical sever

CVE-2025-29029 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. Rated critical seve

CVE-2023-40838 CRITICAL POC
9.8 Aug 30

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. Rate

CVE-2023-40846 CRITICAL POC
9.8 Aug 28

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. Rated critic

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-2923 CRITICAL POC
9.8 May 27

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Rated critical severity (CVSS 9

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy