Skip to main content

Cp 8050 Firmware CVE-2023-42796

HIGH
Path Traversal (CWE-22)
2023-10-10 productcert@siemens.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Oct 10, 2023 - 11:15 nvd
HIGH 8.8

DescriptionNVD

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint.

This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role.

AnalysisAI

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. This Path Traversal vulnerability could allow attackers to access files and directories outside the intended path.

Technical ContextAI

This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint. This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role. Affected products include: Siemens Cp-8050 Firmware, Siemens Cp-8031 Firmware.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.

Share

CVE-2023-42796 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy