Skip to main content

Junos CVE-2023-28972

MEDIUM
Improper Link Resolution Before File Access (CWE-59)
2023-04-17 sirt@juniper.net
6.8
CVSS 3.1 · Vendor: juniper
Share

Severity by source

Vendor (juniper) PRIMARY
6.8 MEDIUM
AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (juniper) · only source for this CVE.

CVSS VectorVendor: juniper

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 17, 2023 - 22:15 cve.org
MEDIUM 6.8

DescriptionCVE.org

An Improper Link Resolution Before File Access vulnerability in console port access of Juniper Networks Junos OS on NFX Series allows an attacker to bypass console access controls. When "set system ports console insecure" is enabled, root login is disallowed for Junos OS as expected. However, the root password can be changed using "set system root-authentication plain-text-password" on NFX Series systems, leading to a possible administrative bypass with physical access to the console. Password recovery, changing the root password from a console, should not have been allowed from an insecure console. This is similar to the vulnerability described in CVE-2019-0035 but affects different platforms and in turn requires a different fix. This issue affects Juniper Networks Junos OS on NFX Series: 19.2 versions prior to 19.2R3-S7; 19.3 versions prior to 19.3R3-S8; 19.4 versions prior to 19.4R3-S12; 20.2 versions prior to 20.2R3-S8; 20.4 versions prior to 20.4R3-S7; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S2; 22.1 versions prior to 22.1R3-S1; 22.2 versions prior to 22.2R2-S1, 22.2R3; 22.3 versions prior to 22.3R1-S2, 22.3R2.

AnalysisAI

An Improper Link Resolution Before File Access vulnerability in console port access of Juniper Networks Junos OS on NFX Series allows an attacker to bypass console access controls. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-59. An Improper Link Resolution Before File Access vulnerability in console port access of Juniper Networks Junos OS on NFX Series allows an attacker to bypass console access controls. When "set system ports console insecure" is enabled, root login is disallowed for Junos OS as expected. However, the root password can be changed using "set system root-authentication plain-text-password" on NFX Series systems, leading to a possible administrative bypass with physical access to the console. Password recovery, changing the root password from a console, should not have been allowed from an insecure console. This is similar to the vulnerability described in CVE-2019-0035 but affects different platforms and in turn requires a different fix.2 versions prior to 19.2R3-S7; 19.3 versions prior to 19.3R3-S8; 19.4 versions prior to 19.4R3-S12; 20.2 versions prior to 20.2R3-S8; 20.4 versions prior to 20.4R3-S7; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S3; 21.4 versions prior to 21.4R3-S2; 22.1 versions prior to 22.1R3-S1; 22.2 versions prior to 22.2R2-S1, 22.2R3; 22.3 versions prior to 22.3R1-S2, 22.3R2. Affected products include: Juniper Junos. Version information: prior to 19.2.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

More in Junos

View all
CVE-2016-1285 MEDIUM
6.8 Mar 09

named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 does not properly handle DNAME records when parsing fe

CVE-2016-1286 HIGH
8.6 Mar 09

named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 allows remote attackers to cause a denial of service (

CVE-2023-36845 CRITICAL POC
9.8 Aug 17

A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series and SRX Series all

CVE-2013-6618 CRITICAL POC
9.0 Nov 05

jsdm/ajax/port.php in J-Web in Juniper Junos before 10.4R13, 11.4 before 11.4R7, 12.1 before 12.1R5, 12.2 before 12.2R3,

CVE-2014-6380 HIGH POC
7.8 Oct 14

Juniper Junos 11.4 before R11, 12.1 before R9, 12.1X44 before D30, 12.1X45 before D20, 12.1X46 before D15, 12.1X47 befor

CVE-2021-0253 HIGH POC
7.8 Apr 22

NFX Series devices using Juniper Networks Junos OS are susceptible to a local command execution vulnerability thereby al

CVE-2021-0252 HIGH POC
7.8 Apr 22

NFX Series devices using Juniper Networks Junos OS are susceptible to a local code execution vulnerability thereby allow

CVE-2019-0053 HIGH POC
7.8 Jul 11

Insufficient validation of environment variables in the telnet client supplied in Junos OS can lead to stack-based buffe

CVE-2023-22415 HIGH POC
7.5 Jan 13

An Out-of-Bounds Write vulnerability in the H.323 ALG of Juniper Networks Junos OS allows an unauthenticated, network-ba

CVE-2022-22223 HIGH POC
7.5 Oct 18

On QFX10000 Series devices using Juniper Networks Junos OS when configured as transit IP/MPLS penultimate hop popping (P

CVE-2022-22209 HIGH POC
7.5 Jul 20

A Missing Release of Memory after Effective Lifetime vulnerability in the kernel of Juniper Networks Junos OS allows an

CVE-2022-22188 HIGH POC
7.5 Apr 14

An Uncontrolled Memory Allocation vulnerability leading to a Heap-based Buffer Overflow in the packet forwarding engine

Share

CVE-2023-28972 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy