Eos
CVE-2023-24512
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Access control enforcement
MITRE ATT&CK
1 technique across 1 tactic: Defense Evasion The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 6.5 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-284. On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision Affected products include: Arista Eos, Arista Ceos-Lab, Arista Cloudeos, Arista Veos-Lab.
Know when Eos gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Affected Products (CPE)NVD
GNU Bash through 4.3 processes trailing strings after function definitions in the values of environment variables, which
GNU Bash through 4.3 bash43-025 processes trailing strings after certain malformed function definitions in the values of
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execut
Remote code execution in OpenSSH's sshd server (regression of CVE-2006-5051) allows unauthenticated remote attackers to
Tunnel decapsulation logic in Arista EOS fails to verify the encapsulation protocol type, allowing any tunneled packet d
Command injection in Arista EOS-based products lets an authenticated user of the gRPC Network Security Interface (gNSI)
The C+ mode offload emulation in the RTL8139 network card device model in QEMU, as used in Xen 4.5.x and earlier, allows
On affected modular platforms running Arista EOS equipped with both redundant supervisor modules and having the redundan
Heap-based buffer overflow in the PCNET controller in QEMU allows remote attackers to execute arbitrary code by sending
Arista EOS before 4.11.12, 4.12 before 4.12.11, 4.13 before 4.13.14M, 4.14 before 4.14.5FX.5, and 4.15 before 4.15.0FX1.
On affected platforms running Arista EOS with mirroring to multiple destinations configured, an internal system error ma
On affected platforms running Arista EOS with SNMP configured, a specially crafted packet can cause a memory leak in the
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB