Skip to main content

Spa112 Firmware CVE-2023-20126

CRITICAL
Missing Authentication for Critical Function (CWE-306)
2023-05-04 psirt@cisco.com
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
May 04, 2023 - 20:15 nvd
CRITICAL 9.8

DescriptionNVD

A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability.

AnalysisAI

A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. A vulnerability in the web-based management interface of Cisco SPA112 2-Port Phone Adapters could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to a missing authentication process within the firmware upgrade function. An attacker could exploit this vulnerability by upgrading an affected device to a crafted version of firmware. A successful exploit could allow the attacker to execute arbitrary code on the affected device with full privileges. Cisco has not released firmware updates to address this vulnerability. Affected products include: Cisco Spa112 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Require authentication for all sensitive operations, implement defense in depth.

CVE-2019-15258 MEDIUM POC
6.5 Oct 16

A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allo

CVE-2019-15252 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15251 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15250 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15249 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15248 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15247 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15246 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15245 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15244 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15243 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

CVE-2019-15242 HIGH
8.0 Oct 16

Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent

Share

CVE-2023-20126 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy