Yellobrik Pec 1864 Firmware
CVE-2023-0750
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Yellobrik PEC-1864 implements authentication checks via javascript in the frontend interface. When the device can be accessed over the network an attacker could bypass authentication.
This would allow an attacker to :
- Change the password, resulting in a DOS of the users
- Change the streaming source, compromising the integrity of the stream
- Change the streaming destination, compromising the confidentiality of the stream
This issue affects Yellowbrik: PEC 1864. No patch has been issued by the manufacturer as this model was discontinued.
AnalysisAI
Yellobrik PEC-1864 implements authentication checks via javascript in the frontend interface. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-602. Yellobrik PEC-1864 implements authentication checks via javascript in the frontend interface. When the device can be accessed over the network an attacker could bypass authentication. This would allow an attacker to : - Change the password, resulting in a DOS of the users - Change the streaming source, compromising the integrity of the stream - Change the streaming destination, compromising the confidentiality of the stream No patch has been issued by the manufacturer as this model was discontinued. Affected products include: Lynx-Technik Yellobrik Pec 1864 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Same technique Authentication Bypass
View allShare
External POC / Exploit Code