Access Appliance CVE-2022-46411

HIGH
Improper Authentication (CWE-287)
2022-12-04 cve@mitre.org
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Dec 04, 2022 - 05:15 nvd
HIGH 8.8

DescriptionNVD

An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. A default password is persisted after installation and may be discovered and used to escalate privileges.

AnalysisAI

An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Improper Authentication (CWE-287), which allows attackers to bypass authentication mechanisms to gain unauthorized access. An issue was discovered in Veritas NetBackup Flex Scale through 3.0 and Access Appliance through 8.0.100. A default password is persisted after installation and may be discovered and used to escalate privileges. Affected products include: Veritas Access Appliance, Veritas Netbackup Flex Scale Appliance. Version information: through 3.0.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement multi-factor authentication, enforce strong password policies, use proven authentication frameworks.