Flir Ax8 Firmware
CVE-2022-37060
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Lifecycle Timeline
1DescriptionNVD
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.
AnalysisAI
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16. Affected products include: Flir Flir Ax8 Firmware. Version information: version 1.49.16.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
More in Flir Ax8 Firmware
View allAll FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. Rate
Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows attackers to run arbitrary commands
A vulnerability has been found in Teledyne FLIR AX8 up to 1.46.16. Rated medium severity (CVSS 5.5), this vulnerability
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting (XSS) du
FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access
A flaw has been found in Teledyne FLIR AX8 up to 1.46.16. Rated low severity (CVSS 2.1), this vulnerability is remotely
A vulnerability was found in Teledyne FLIR AX8 up to 1.46.16. Rated high severity (CVSS 7.4), this vulnerability is remo
Same weakness CWE-22 – Path Traversal
View allSame technique Path Traversal
View allShare
External POC / Exploit Code
Leaving vuln.today