Skip to main content

Mypro CVE-2021-22657

CRITICAL
OS Command Injection (CWE-78)
2021-12-23 ics-cert@hq.dhs.gov
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could execute arbitrary operating system commands on the host by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 1.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter. Affected products include: Myscada Mypro.

Know when Mypro gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

mySCADA myPRO: Versions 8.20.0 and prior has a feature where the API password can be specified, which may allow an attacker to inject arbitrary operating system commands through a specific parameter.

Threat Intelligence Overview

EPSS Score
1.2%
Top 35% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 1.2%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)NVD

cpe:2.3:a:myscada:mypro:*:*:*:*:*:*:*:*

More in Mypro

View all
CVE-2025-24865 CRITICAL POC
10.0 Feb 13

The administrative web interface of mySCADA myPRO Manager can be accessed without authentication which could allow an un

CVE-2025-22896 CRITICAL POC
9.2 Feb 13

mySCADA myPRO Manager stores credentials in cleartext, which could allow an attacker to obtain sensitive information. Ra

CVE-2023-28384 HIGH POC
8.8 Apr 27

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary ope

CVE-2018-11311 CRITICAL POC
9.1 May 20

A hardcoded FTP username of myscada and password of Vikuk63 in 'myscadagate.exe' in mySCADA myPRO 7 allows remote attack

CVE-2021-44453 CRITICAL
9.8 Dec 23

mySCADA myPRO: Versions 8.20.0 and prior has a vulnerable debug interface which includes a ping utility, which may allow

CVE-2021-43987 CRITICAL
9.8 Dec 23

An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not expose

CVE-2021-43985 CRITICAL
9.8 Dec 23

An unauthenticated remote attacker can access mySCADA myPRO Versions 8.20.0 and prior without any form of authentication

CVE-2021-43984 CRITICAL
9.8 Dec 23

mySCADA myPRO: Versions 8.20.0 and prior has a feature where the firmware can be updated, which may allow an attacker to

CVE-2021-43981 CRITICAL
9.8 Dec 23

mySCADA myPRO: Versions 8.20.0 and prior has a feature to send emails, which may allow an attacker to inject arbitrary o

CVE-2021-23198 CRITICAL
9.8 Dec 23

mySCADA myPRO: Versions 8.20.0 and prior has a feature where the password can be specified, which may allow an attacker

CVE-2025-25067 CRITICAL
9.3 Feb 13

mySCADA myPRO Manager is vulnerable to an OS command injection which could allow a remote attacker to execute arbitrary

CVE-2024-4708 CRITICAL
9.3 Jul 02

mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy