Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A02:2025 - Security Misconfiguration
ASVS 5.0
V13 - Configuration XML external entity prevention
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.2 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could read arbitrary files or perform SSRF through XML processing by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 1.8% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Disable external entity processing in XML parsers, use JSON instead of XML where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as XML External Entity (XXE) (CWE-611), which allows attackers to read arbitrary files or perform SSRF through XML processing. Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets. Affected products include: Mitsubishi G-50A Firmware, Mitsubishi Gb-50A Firmware, Mitsubishi Ag-150A-A Firmware, Mitsubishi Ag-150A-J Firmware, Mitsubishi Gb-50Ada-A Firmware.

Know when G 50A Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.2 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
High

DescriptionNVD

Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.

Threat Intelligence Overview

EPSS Score
1.8%
Top 24% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 1.8%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

43
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +41
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

XML External Entity (XXE) attacks exploit XML parsers that process Document Type Definitions (DTDs) without proper restrictions.

Affected Products (CPE)NVD

cpe:2.3:o:mitsubishi:g-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:gb-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ag-150a-a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ag-150a-j_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:gb-50ada-a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:gb-50ada-j_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:eb-50gu-a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:eb-50gu-j_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ae-200a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ae-200e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ae-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ae-50e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ew-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:ew-50e_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:te-200a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:te-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:tw-50a_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:cms-rmd-j_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:mitsubishi:pac-yg50eca_firmware:*:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy