G 50A Firmware
CVE-2021-20595
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A02:2025 - Security Misconfiguration
ASVS 5.0
V13 - Configuration XML external entity prevention
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.2 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could read arbitrary files or perform SSRF through XML processing by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Disable external entity processing in XML parsers, use JSON instead of XML where possible.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as XML External Entity (XXE) (CWE-611), which allows attackers to read arbitrary files or perform SSRF through XML processing. Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets. Affected products include: Mitsubishi G-50A Firmware, Mitsubishi Gb-50A Firmware, Mitsubishi Ag-150A-A Firmware, Mitsubishi Ag-150A-J Firmware, Mitsubishi Gb-50Ada-A Firmware.
Know when G 50A Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
XML External Entity (XXE) attacks exploit XML parsers that process Document Type Definitions (DTDs) without proper restrictions.
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB