Skip to main content

Apexpro Telemetry Server Firmware CVE-2020-6964

HIGH
Missing Authentication for Critical Function (CWE-306)
2020-01-24 ics-cert@hq.dhs.gov
8.6
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.6 HIGH
AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Changed
Confidentiality
None
Integrity
High
Availability
None

Lifecycle Timeline

1
CVE Published
Jan 24, 2020 - 17:15 nvd
HIGH 8.6

DescriptionNVD

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.

AnalysisAI

In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and. Rated high severity (CVSS 8.6), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network. Affected products include: Gehealthcare Apexpro Telemetry Server Firmware, Gehealthcare Carescape Central Station Mai700 Firmware, Gehealthcare Carescape Central Station Mas700 Firmware, Gehealthcare Clinical Information Center Mp100D Firmware, Gehealthcare Clinical Information Center Mp100R Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Require authentication for all sensitive operations, implement defense in depth.

Share

CVE-2020-6964 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy