Skip to main content

Connect Secure CVE-2020-15352

HIGH
Improper Restriction of XML External Entity Reference (CWE-611)
2020-10-27 cve@mitre.org
7.2
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.2 HIGH
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Oct 27, 2020 - 05:15 nvd
HIGH 7.2

DescriptionNVD

An XML external entity (XXE) vulnerability in Pulse Connect Secure (PCS) before 9.1R9 and Pulse Policy Secure (PPS) before 9.1R9 allows remote authenticated admins to conduct server-side request forgery (SSRF) attacks via a crafted DTD in an XML request.

AnalysisAI

An XML external entity (XXE) vulnerability in Pulse Connect Secure (PCS) before 9.1R9 and Pulse Policy Secure (PPS) before 9.1R9 allows remote authenticated admins to conduct server-side request. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as XML External Entity (XXE) (CWE-611), which allows attackers to read arbitrary files or perform SSRF through XML processing. An XML external entity (XXE) vulnerability in Pulse Connect Secure (PCS) before 9.1R9 and Pulse Policy Secure (PPS) before 9.1R9 allows remote authenticated admins to conduct server-side request forgery (SSRF) attacks via a crafted DTD in an XML request. Affected products include: Ivanti Connect Secure, Pulsesecure Pulse Connect Secure, Ivanti Policy Secure, Pulsesecure Pulse Policy Secure. Version information: before 9.1.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Disable external entity processing in XML parsers, use JSON instead of XML where possible.

CVE-2024-21887 CRITICAL POC
9.1 Jan 12

Ivanti Connect Secure and Policy Secure contain an authenticated command injection in web components allowing administra

CVE-2023-46805 HIGH POC
8.2 Jan 12

Ivanti Connect Secure and Policy Secure contain an authentication bypass in the web component allowing unauthenticated a

CVE-2024-21893 HIGH POC
8.2 Jan 31

Ivanti Connect Secure and Policy Secure contain an SSRF vulnerability in the SAML component allowing unauthenticated acc

CVE-2025-0282 CRITICAL POC
9.0 Jan 08

Ivanti Connect Secure, Policy Secure, and Neurons for ZTA contain a stack-based buffer overflow allowing unauthenticated

CVE-2025-22457 CRITICAL POC
9.8 Apr 03

Remote code execution in Ivanti Connect Secure (before 22.7R2.6), Ivanti Policy Secure (before 22.7R1.4), and Ivanti ZTA

CVE-2021-22893 CRITICAL
10.0 Apr 23

Pulse Connect Secure 9.0R3/9.1R1 and higher is vulnerable to an authentication bypass vulnerability exposed by the Windo

CVE-2025-22467 CRITICAL
9.9 Feb 11

A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.6 allows a remote authenticated attacker to

CVE-2024-37404 HIGH POC
8.8 Oct 18

Improper Input Validation in the admin portal of Ivanti Connect Secure before 22.7R2.1 and 9.1R18.9, or Ivanti Policy Se

CVE-2020-8260 HIGH POC
7.2 Oct 28

A vulnerability in the Pulse Connect Secure < 9.1R9 admin web interface could allow an authenticated attacker to perform

CVE-2019-11539 HIGH POC
7.2 Apr 26

In Pulse Secure Pulse Connect Secure version 9.0RX before 9.0R3.4, 8.3RX before 8.3R7.1, 8.2RX before 8.2R12.1, and 8.1R

CVE-2024-21894 CRITICAL POC
9.8 Apr 04

A heap overflow vulnerability in IPSec component of Ivanti Connect Secure (9.x, 22.x) and Ivanti Policy Secure allows an

CVE-2019-11540 CRITICAL POC
9.8 Apr 26

In Pulse Secure Pulse Connect Secure version 9.0RX before 9.0R3.4 and 8.3RX before 8.3R7.1 and Pulse Policy Secure versi

Share

CVE-2020-15352 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy