Pb610 Panel Builder 600 Firmware
CVE-2019-7227
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK
2 techniques across 2 tactics: Discovery, Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.3 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | An attacker could exploit this vulnerability to access files and directories outside the intended path. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. Rated high severity (CVSS 7.3), this vulnerability is low attack complexity. Public exploit code available.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker. Affected products include: Abb Pb610 Panel Builder 600 Firmware.
Know when Pb610 Panel Builder 600 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.
Affected Products (CPE)NVD
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication a
The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Rated high
The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. Rated high
The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Rated high severity (
The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. Rate
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB