Simatic Wincc Oa Ui CVE-2018-4844

MEDIUM
Improper Access Control (CWE-284)
2018-03-20 productcert@siemens.com
6.7
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
6.7 MEDIUM
AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

Lifecycle Timeline

1
CVE Published
Mar 20, 2018 - 14:29 nvd
MEDIUM 6.7

DescriptionNVD

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

AnalysisAI

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Rated medium severity (CVSS 6.7), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-284. A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. Affected products include: Siemens Simatic Wincc Oa Ui.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.