Skip to main content

I5 Application Firmware CVE-2018-19073

HIGH
OS Command Injection (CWE-78)
2018-11-07 cve@mitre.org
7.2
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
7.2 HIGH
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Nov 07, 2018 - 18:29 nvd
HIGH 7.2

DescriptionNVD

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow attackers to execute arbitrary OS commands via shell metacharacters in the modelName, by leveraging /mnt/mtd/app/config/ProductConfig.xml write access.

AnalysisAI

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow attackers to execute arbitrary OS commands via shell metacharacters in the modelName, by leveraging /mnt/mtd/app/config/ProductConfig.xml write access. Affected products include: Opticam I5 Application Firmware, Opticam I5 System Firmware, Foscam C2 Application Firmware, Foscam C2 System Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

CVE-2018-19082 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128.

CVE-2018-19081 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128.

CVE-2018-19078 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128.

CVE-2018-19076 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19069 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19067 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19064 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19063 CRITICAL POC
9.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19071 HIGH POC
7.8 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

CVE-2018-19079 HIGH POC
7.5 Nov 07

An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128.

CVE-2018-19077 HIGH POC
7.5 Nov 07

An issue was discovered on Foscam Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128.

CVE-2018-19074 HIGH POC
7.5 Nov 07

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Optic

Share

CVE-2018-19073 vulnerability details – vuln.today