Nsg 9000 Firmware
CVE-2018-14942
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Harmonic NSG 9000 devices allow remote authenticated users to conduct directory traversal attacks, as demonstrated by "POST /PY/EMULATION_GET_FILE" or "POST /PY/EMULATION_EXPORT" with FileName=../../../passwd in the POST data.
AnalysisAI
Harmonic NSG 9000 devices allow remote authenticated users to conduct directory traversal attacks, as demonstrated by "POST /PY/EMULATION_GET_FILE" or "POST /PY/EMULATION_EXPORT" with. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. Harmonic NSG 9000 devices allow remote authenticated users to conduct directory traversal attacks, as demonstrated by "POST /PY/EMULATION_GET_FILE" or "POST /PY/EMULATION_EXPORT" with FileName=../../../passwd in the POST data. Affected products include: Harmonicinc Nsg 9000 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
More in Nsg 9000 Firmware
View allSame weakness CWE-22 – Path Traversal
View allSame technique Path Traversal
View allShare
External POC / Exploit Code
Leaving vuln.today