Skip to main content

Scalance M875 Firmware CVE-2018-11448

MEDIUM
Cross-Site Request Forgery (CSRF) (CWE-352)
2018-06-26 productcert@siemens.com
4.8
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
4.8 MEDIUM
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Jun 26, 2018 - 18:29 nvd
MEDIUM 4.8

DescriptionNVD

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.

AnalysisAI

A vulnerability has been identified in SCALANCE M875 (All versions). Rated medium severity (CVSS 4.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Request Forgery (CSRF) (CWE-352), which allows attackers to trick authenticated users into performing unintended actions. A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known. Affected products include: Siemens Scalance M875 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement anti-CSRF tokens, validate Origin/Referer headers, use SameSite cookie attribute.

Share

CVE-2018-11448 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy