Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK

2 techniques across 2 tactics: Discovery, Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 10.0 (CRITICAL). Attack characteristics: network attack vector, low complexity. EPSS exploitation probability: 18.90%.

Exploit ScenarioDerived

A remote attacker could access files and directories outside the intended path by sending crafted requests to the affected application.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 18.9% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, low attack complexity. Epss exploitation probability 18.9%.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. Affected products include: Schneider-Electric Stbnic2212 Firmware, Schneider-Electric Stbnip2212 Firmware, Schneider-Electric Tsxetc0101 Firmware, Schneider-Electric Tsxetc100 Firmware, Schneider-Electric Tsxp573623Mc Firmware. Version information: before 5.5.

Know when Modicon M340 Bmxp342020 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 10.0 CRITICAL
AV:N/AC:L/Au:N/C:C/I:C/A:C

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Confidentiality
C
Integrity
C
Availability
C

DescriptionCVE.org

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request.

Threat Intelligence Overview

EPSS Score
18.9%
Top 5% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 18.9%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

69
Low Medium High Critical
KEV: 0
EPSS: +19
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.

Affected Products (CPE)CVE.org

cpe:2.3:o:schneider-electric:stbnic2212_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:stbnip2212_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxetc0101_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxetc100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp573623mc_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety110ws_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp574634m_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety110wsc_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp574823am_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety4103_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp574823m_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety4103c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp574823mc_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety5103_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp575634m_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxety5103c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxp576634m_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxetz410_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxwmy100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:schneider-electric:tsxetz510_firmware:-:*:*:*:*:*:*:*
+ 53 more
CVE-2022-37300 CRITICAL
9.8 Sep 12

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized ac

CVE-2020-7540 CRITICAL
9.8 Dec 11

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy O

CVE-2018-7761 CRITICAL
9.8 Apr 18

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum

CVE-2018-7760 CRITICAL
9.8 Apr 18

An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC,

CVE-2018-7242 CRITICAL
9.8 Apr 18

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200

CVE-2018-7241 CRITICAL
9.8 Apr 18

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 control

CVE-2021-22779 CRITICAL
9.1 Jul 14

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, i

CVE-2020-7534 HIGH
8.8 Feb 04

A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sen

CVE-2017-6017 HIGH
7.5 Jun 30

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BM

CVE-2021-22788 HIGH
7.5 Feb 11

A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a speciall

CVE-2021-22787 HIGH
7.5 Feb 11

A CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of the device when an attack

CVE-2021-22785 HIGH
7.5 Feb 11

A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy