Winlog Pro
CVE-2012-4356
MEDIUM
Severity by source
AV:N/AC:M/Au:N/C:P/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
AV:N/AC:M/Au:N/C:P/I:N/A:N
Lifecycle Timeline
1DescriptionCVE.org
Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98.
AnalysisAI
Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable. Public exploit code available and EPSS exploitation probability 60.6%.
Technical ContextAI
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. (dot dot) in a pathname, followed by a file-read operation with opcode (1) 0x96, (2) 0x97, or (3) 0x98. Affected products include: Sielcosistemi Winlog Pro, Sielcosistemi Winlog Lite. Version information: before 2.07.17.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
More in Winlog Pro
View allBuffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 al
TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote at
TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote at
Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might allow rem
Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA befor
Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of
Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return value of
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro
Same weakness CWE-22 – Path Traversal
View allSame technique Path Traversal
View allShare
External POC / Exploit Code
Leaving vuln.today