CVE-2026-82684 Sep 04, 21:01 HIGH CISA Act Now

Missing authorization enforcement in Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior allows low-privilege authenticated users to access restricted endpoints and extract system credentials, device configurations, and raw flash memory contents. Disclosed by CISA ICS-CERT under advisory ICSA-26-246-08, this affects an OT-class DC power monitoring appliance where credential extraction could enable full device takeover. No active exploitation or public proof-of-concept has been identified at time of analysis, but the straightforward exploitation path and ICS context elevate real-world risk.

Authentication Bypass Tpdin Monitor Web3 Tycon Systems
NVD GitHub
CVSS 4.0
8.6
EPSS
0.5%
CVE-2026-61884 Jul 24, 21:40 CRITICAL CISA Emergency

Remote authentication bypass in Tycon Systems TPDIN-Monitor-WEB2 allows unauthenticated attackers to gain full administrative access by submitting empty credentials. This enables control of power relays, device reboot, and network configuration, potentially causing physical equipment damage. No active exploitation or public exploit has been reported at this time.

Authentication Bypass Tpdin Monitor Web2 Tycon Systems
NVD GitHub VulDB
CVSS 4.0
9.3
EPSS
0.7%
CVE-2026-55985 Jul 24, 21:37 MEDIUM CISA This Month

Cleartext credential storage in Tycon Systems TPDIN-Monitor-WEB2 web management interface allows authenticated attackers to view system credentials, potentially leading to compromise of other network systems. Affected version is 2.3.9. No active exploitation or public exploit is known, and EPSS indicates a very low probability of exploitation.

Information Disclosure Tpdin Monitor Web2 Tycon Systems
NVD GitHub VulDB
CVSS 4.0
5.3
EPSS
0.1%
EPSS 0% CVSS 8.6
HIGH Act Now

Missing authorization enforcement in Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior allows low-privilege authenticated users to access restricted endpoints and extract system credentials, device configurations, and raw flash memory contents. Disclosed by CISA ICS-CERT under advisory ICSA-26-246-08, this affects an OT-class DC power monitoring appliance where credential extraction could enable full device takeover. No active exploitation or public proof-of-concept has been identified at time of analysis, but the straightforward exploitation path and ICS context elevate real-world risk.

Authentication Bypass Tpdin Monitor Web3 Tycon Systems
NVD GitHub
EPSS 1% CVSS 9.3
CRITICAL Emergency

Remote authentication bypass in Tycon Systems TPDIN-Monitor-WEB2 allows unauthenticated attackers to gain full administrative access by submitting empty credentials. This enables control of power relays, device reboot, and network configuration, potentially causing physical equipment damage. No active exploitation or public exploit has been reported at this time.

Authentication Bypass Tpdin Monitor Web2 Tycon Systems
NVD GitHub VulDB
EPSS 0% CVSS 5.3
MEDIUM This Month

Cleartext credential storage in Tycon Systems TPDIN-Monitor-WEB2 web management interface allows authenticated attackers to view system credentials, potentially leading to compromise of other network systems. Affected version is 2.3.9. No active exploitation or public exploit is known, and EPSS indicates a very low probability of exploitation.

Information Disclosure Tpdin Monitor Web2 Tycon Systems
NVD GitHub VulDB

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy