Skip to main content

Prosoft Technology

4 CVEs vendor

Monthly

CVE-2017-20236 Apr 03, 22:54 CRITICAL Act Now

ProSoft Technology ICX35-HWC versions 1.3 and prior cellular gateways contain an input validation vulnerability in the web user interface that allows remote attackers to inject and execute system. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Icx35 Hwc Cellular Gateway Prosoft Technology
NVD VulDB
CVSS 4.0
9.3
EPSS
0.1%
CVE-2017-20235 Apr 03, 22:51 CRITICAL Act Now

ProSoft Technology ICX35-HWC version 1.3 and prior cellular gateways contain an authentication bypass vulnerability in the web user interface that allows unauthenticated attackers to gain access to. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Icx35 Hwc Cellular Gateway Prosoft Technology
NVD VulDB
CVSS 4.0
9.3
EPSS
0.0%
CVE-2021-22661 Feb 26, 15:15 HIGH This Week

Changing the password on the module webpage does not require the user to type in the current password first. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Privilege Escalation Icx35 Hwc A Firmware Icx35 Hwc E Firmware Prosoft Technology
NVD
CVSS 3.1
7.5
EPSS
1.0%
CVE-2013-2803 Sep 09, 11:39 CRITICAL Act Now

ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure Radiolinx Controlscape Prosoft Technology
NVD
CVSS 2.0
9.3
EPSS
0.6%
EPSS 0% CVSS 9.3
CRITICAL Act Now

ProSoft Technology ICX35-HWC versions 1.3 and prior cellular gateways contain an input validation vulnerability in the web user interface that allows remote attackers to inject and execute system. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Command Injection Icx35 Hwc Cellular Gateway Prosoft Technology
NVD VulDB
EPSS 0% CVSS 9.3
CRITICAL Act Now

ProSoft Technology ICX35-HWC version 1.3 and prior cellular gateways contain an authentication bypass vulnerability in the web user interface that allows unauthenticated attackers to gain access to. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Icx35 Hwc Cellular Gateway Prosoft Technology
NVD VulDB
EPSS 1% CVSS 7.5
HIGH This Week

Changing the password on the module webpage does not require the user to type in the current password first. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Privilege Escalation Icx35 Hwc A Firmware Icx35 Hwc E Firmware +1
NVD
EPSS 1% CVSS 9.3
CRITICAL Act Now

ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure Radiolinx Controlscape Prosoft Technology
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy