CVE-2020-7547 Dec 01, 15:15 HIGH This Week

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Power Manager Ecostruxure Power Monitoring Expert Ecostruxure Energy Expert +2
NVD
CVSS 3.1
8.8
EPSS
1.3%
CVE-2020-7546 Dec 01, 15:15 MEDIUM This Month

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

XSS Schneider Electric Power Manager Ecostruxure Power Monitoring Expert Ecostruxure Energy Expert +2
NVD
CVSS 3.1
5.4
EPSS
0.6%
CVE-2020-7545 Dec 01, 15:15 HIGH This Week

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass RCE Schneider Electric Power Manager Ecostruxure Power Monitoring Expert +3
NVD
CVSS 3.1
7.2
EPSS
2.0%
EPSS 1% CVSS 8.8
HIGH This Week

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Power Manager +4
NVD
EPSS 1% CVSS 5.4
MEDIUM This Month

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

XSS Schneider Electric Power Manager +4
NVD
EPSS 2% CVSS 7.2
HIGH This Week

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.