Skip to main content

Isagraf Workbench

4 CVEs product

Monthly

CVE-2022-2465 Aug 25, 18:15 HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

RCE Deserialization Rockwell Isagraf Workbench Rockwellautomation
NVD
CVSS 3.1
7.8
EPSS
0.3%
CVE-2022-2464 Aug 25, 18:15 HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

Path Traversal Rockwell Isagraf Workbench Rockwellautomation
NVD
CVSS 3.1
7.8
EPSS
0.3%
CVE-2022-2463 Aug 25, 18:15 HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

Path Traversal Microsoft Rockwell Isagraf Workbench Rockwellautomation
NVD
CVSS 3.1
7.8
EPSS
2.6%
CVE-2022-1118 May 17, 20:15 HIGH This Week

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Deserialization Safety Instrumented Systems Workstation Connected Component Workbench Isagraf Workbench +1
NVD
CVSS 3.1
7.8
EPSS
11.7%
EPSS 0% CVSS 7.8
HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

RCE Deserialization Rockwell +2
NVD
EPSS 0% CVSS 7.8
HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

Path Traversal Rockwell Isagraf Workbench +1
NVD
EPSS 3% CVSS 7.8
HIGH PATCH This Week

Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity.

Path Traversal Microsoft Rockwell +2
NVD
EPSS 12% CVSS 7.8
HIGH This Week

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Deserialization Safety Instrumented Systems Workstation +3
NVD