Skip to main content

Central Ac Unit Firmware

4 CVEs product

Monthly

CVE-2023-24504 MEDIUM This Month

Electra Central AC unit - Adjacent attacker may cause the unit to connect to unauthorized update server. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD
CVSS 3.1
6.5
EPSS
0.3%
CVE-2023-24502 MEDIUM This Month

Electra Central AC unit - The unit opens an AP with an easily calculated password. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Central Ac Unit Firmware
NVD
CVSS 3.1
6.5
EPSS
0.2%
CVE-2023-24501 CRITICAL Act Now

Electra Central AC unit - Hardcoded Credentials in unspecified code used by the unit. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD
CVSS 3.1
9.8
EPSS
0.6%
CVE-2023-24500 MEDIUM This Month

Electra Central AC unit - Adjacent attacker may cause the unit to load unauthorized FW. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD
CVSS 3.1
6.5
EPSS
0.2%
EPSS 0% CVSS 6.5
MEDIUM This Month

Electra Central AC unit - Adjacent attacker may cause the unit to connect to unauthorized update server. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

Electra Central AC unit - The unit opens an AP with an easily calculated password. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Central Ac Unit Firmware
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

Electra Central AC unit - Hardcoded Credentials in unspecified code used by the unit. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

Electra Central AC unit - Adjacent attacker may cause the unit to load unauthorized FW. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Central Ac Unit Firmware
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy