CVE-2025-41753 Oct 01, 06:42 CRITICAL PATCH Act Now

Unauthenticated remote attackers can read or overwrite arbitrary files on affected WAGO controllers by creating a BACnet File Object whose object name is used as a file path without adequate validation, allowing directory traversal out of the intended storage location and potentially leading to full device compromise. The affected lines are the WAGO 0751-9x01, 0750-811x/0750-821x, 0762-420x/430x/520x/530x/620x/630x-8000 and 0752-8303-8000-0002 controllers; exploitation requires network reachability to the device's BACnet/IP service, but no authentication (PR:N) and no user interaction (UI:N) are needed, and dynamically creating a BACnet File Object is a standard protocol operation rather than a hidden feature. There is no public exploit identified at time of analysis and the issue is not confirmed actively exploited (no CISA KEV listing); the practical limiting factor is exposure, since these controllers normally sit on building-automation or industrial networks, so an attacker would need direct access, a flat network, or a compromised adjacent host to reach the BACnet endpoint. This is a genuine high-priority issue, not a CVSS-inflation artifact, as reflected in the CERTVDE advisory VDE-2025-102.

Path Traversal Wago 0751 9X01 0750 811X Xxxx Xxxx 0750 821X Xxx Xxx +8
NVD VulDB
CVSS 4.0
9.3
EPSS
0.6%
EPSS 1% CVSS 9.3
CRITICAL PATCH Act Now

Unauthenticated remote attackers can read or overwrite arbitrary files on affected WAGO controllers by creating a BACnet File Object whose object name is used as a file path without adequate validation, allowing directory traversal out of the intended storage location and potentially leading to full device compromise. The affected lines are the WAGO 0751-9x01, 0750-811x/0750-821x, 0762-420x/430x/520x/530x/620x/630x-8000 and 0752-8303-8000-0002 controllers; exploitation requires network reachability to the device's BACnet/IP service, but no authentication (PR:N) and no user interaction (UI:N) are needed, and dynamically creating a BACnet File Object is a standard protocol operation rather than a hidden feature. There is no public exploit identified at time of analysis and the issue is not confirmed actively exploited (no CISA KEV listing); the practical limiting factor is exposure, since these controllers normally sit on building-automation or industrial networks, so an attacker would need direct access, a flat network, or a compromised adjacent host to reach the BACnet endpoint. This is a genuine high-priority issue, not a CVSS-inflation artifact, as reflected in the CERTVDE advisory VDE-2025-102.

Path Traversal Wago 0751 9X01 +10
NVD VulDB

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy