SolarView Compact EUVDEUVD-2026-77252

| CVE-2026-82796 MEDIUM
Cross-site Scripting (XSS) (CWE-79)
2026-09-14 jpcert GHSA-rg6m-c69p-7vgm
5.1
CVSS 4.0 · Vendor: jpcert
Share

Severity by source

Vendor (jpcert) PRIMARY
5.1 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
9.0 CRITICAL

Requires authenticated login (PR:L) and victim user interaction (UI:R); XSS escalating to OS command execution on the device constitutes a scope change with full device-level impact.

3.1 AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (jpcert).

CVSS VectorVendor: jpcert

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
A
Scope
X

Lifecycle Timeline

3
Patch available
Sep 14, 2026 - 08:01 EUVD
Analysis Generated
Sep 14, 2026 - 07:35 vuln.today
CVSS changed
Sep 14, 2026 - 07:22 NVD
5.4 (MEDIUM) 5.1 (MEDIUM)

DescriptionCVE.org

SolarView Compact contains a cross-site scripting vulnerability in Image Management. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.

AnalysisAI

Cross-site scripting in the Image Management component of Contec SolarView Compact (models sv-cpt-mc310 and sv-cpt-mc310f) enables authenticated attackers to inject malicious script that can trigger arbitrary OS command execution on the underlying device. Reported by JPCERT/CC (JVNVU97753461) with a Contec vendor advisory, the vulnerability chains CWE-79 XSS with a command injection pathway, making it more dangerous than its CVSS 4.0 score of 5.1 suggests. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires the attacker to hold valid login credentials for the SolarView Compact web interface - the vendor description explicitly states 'an attacker who can log in to the product.' The vulnerable feature is Image Management specifically; access to that section of the interface is a prerequisite. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The official CVSS 4.0 base score of 5.1 (AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N) materially understates the real-world risk on two counts: first, the PR:N metric directly conflicts with the vendor description stating 'an attacker who can log in to the product,' implying at minimum PR:L; second, the VC:N/VI:N/VA:N assignment ignores the explicitly stated arbitrary OS command execution impact on the device itself, which should yield high vulnerable-component impact scores. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Apply the vendor-released patch described in Contec's security advisory (https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_sv_26091000_en.pdf). … Detailed patch versions, workarounds, and compensating controls in full report.

Threat intelligence, references, and detailed analysis are available after sign-in.