Skip to main content

TOTOLINK T6 EUVDEUVD-2026-67908

| CVE-2026-51618 HIGH
Improper Access Control (CWE-284)
2026-08-28 mitre GHSA-j4f4-4qq5-3pgc
7.5
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
vuln.today AI
7.5 HIGH

Unauthenticated single POST over the network with no interaction; only confidentiality impact as data is read-only; C:H retained pending confirmation of credential exposure scope.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (mitre).

CVSS VectorVendor: mitre

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

5
Metadata Corrected
Sep 01, 2026 - 19:40 vuln.today
tag: N A removed
Analysis Generated
Sep 01, 2026 - 19:34 vuln.today
CVSS changed
Sep 01, 2026 - 17:22 NVD
7.5 (HIGH)
CVE Published
Aug 28, 2026 - 00:00 cve.org
HIGH 7.5
CVE Published
Aug 28, 2026 - 00:00 cve.org
UNKNOWN (no severity yet)

DescriptionCVE.org

Incorrect access control in the getWizardCfg function of TOTOLINK T6 4.1.5cu.748_B20211015 allows unauthenticated attackers to obtain setup wizard and onboarding configuration information via sending a crafted POST request to /cgi-bin/cstecgi.cgi.

AnalysisAI

Unauthenticated remote access to setup wizard and onboarding configuration is possible on TOTOLINK T6 firmware 4.1.5cu.748_B20211015 through missing access control on the getWizardCfg CGI handler. Any attacker reachable to the device's web management interface can send a crafted POST to /cgi-bin/cstecgi.cgi and receive wizard configuration data - which may include ISP connection parameters or other sensitive values collected during initial device setup - without supplying credentials. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Target device must be running TOTOLINK T6 firmware 4.1.5cu.748_B20211015. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment CVSS 3.1 scores this at 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N), which is appropriate for the attack vector - fully unauthenticated, single HTTP POST, no user interaction - but whether C:H is accurate hinges on what the wizard configuration actually stores. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation No vendor-released patch version is confirmed in the available data. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: Identify and inventory all TOTOLINK T6 devices running firmware 4.1.5cu.748_B20211015 through device management or vendor documentation, then immediately restrict web management interface access to trusted administrative networks only using firewall rules. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

EUVD-2026-67908 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy