Skip to main content

Tenda EUVDEUVD-2026-17509

| CVE-2026-5204 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-31 VulDB GHSA-5qj8-jcmc-3p6q
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

4
PoC Detected
Apr 02, 2026 - 12:07 vuln.today
Public exploit code
EUVD ID Assigned
Mar 31, 2026 - 16:00 euvd
EUVD-2026-17509
Analysis Generated
Mar 31, 2026 - 16:00 vuln.today
CVE Published
Mar 31, 2026 - 15:45 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability was determined in Tenda CH22 1.0.0.1. Affected is the function formWebTypeLibrary of the file /goform/webtypelibrary of the component Parameter Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.

AnalysisAI

Stack-based buffer overflow in Tenda CH22 router version 1.0.0.1 allows authenticated remote attackers to achieve arbitrary code execution via the webSiteId parameter in the formWebTypeLibrary function. Public exploit code exists on GitHub, significantly lowering the barrier to exploitation. While requiring low-privilege authentication (PR:L), the vulnerability enables complete compromise of router confidentiality, integrity, and availability with low attack complexity.

Technical ContextAI

This vulnerability affects the Tenda CH22 router firmware version 1.0.0.1, specifically within the Parameter Handler component that processes web interface requests. The formWebTypeLibrary function in /goform/webtypelibrary endpoint fails to properly validate input length for the webSiteId parameter before copying it to a fixed-size stack buffer. This is a classic CWE-121 stack-based buffer overflow, where attacker-controlled data exceeds allocated stack memory boundaries. Stack overflows are particularly dangerous in embedded devices like routers because they can overwrite return addresses and function pointers, enabling arbitrary code execution with the privileges of the web server process. The CPE identifier cpe:2.3:a:tenda:ch22:*:*:*:*:*:*:*:* confirms this affects the Tenda CH22 product line, though the specific vulnerable version is 1.0.0.1.

RemediationAI

No vendor-released patch has been identified in the available intelligence at time of analysis. Users should immediately check the Tenda support website at https://www.tenda.com.cn/ for firmware updates newer than version 1.0.0.1 and apply them if available. As interim mitigations, organizations should disable remote administration features to reduce network-based attack surface, change default administrative credentials to complex passwords unique to each device, implement network segmentation to isolate IoT devices including routers from critical systems, and restrict administrative interface access to trusted IP addresses only through firewall rules. Consider replacing affected devices with alternative router models if Tenda does not release a security update within a reasonable timeframe. Monitor the VulDB advisory at https://vuldb.com/vuln/354332 for updates on patch availability. For environments where these devices cannot be immediately replaced or patched, place them behind additional network security controls and monitor for suspicious authentication attempts or unusual outbound traffic patterns.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2025-45429 CRITICAL POC
9.8 Apr 23

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp

Share

EUVD-2026-17509 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy