Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Access control enforcement
MITRE ATT&CK
1 technique across 1 tactic: Defense Evasion The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.1 (CRITICAL). |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 15, 2026
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
Earlier versions of this analysis (1)
RemediationAI
Monitor vendor advisories for patches. Apply mitigations such as network segmentation, access restrictions, and monitoring.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Improper Access Control (CWE-284).
Know when Nshield 5c Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
Lifecycle Timeline
2Executive ViewAI
Entrust HSM appliances (nShield Connect XC, nShield 5c, nShield HSMi up to versions 13.6.11/13.7) contain a critical physical tampering vulnerability allowing attackers with direct device access to extract cryptographic keys without detection. Organizations using these devices for key management in payment systems, PKI, or regulatory-sensitive environments face potential compromise of their entire cryptographic infrastructure.
Implement strict physical security controls: restrict device access to authorized personnel only via locked rooms/cages with access logging and video surveillance; establish tamper-evident seals and regular physical inspections with documented audit trails; consider air-gapped deployment or network segmentation to limit cryptographic key usage if devices are compromised; implement cryptographic key rotation policies and monitor for unauthorized key access or use; for critical applications, evaluate hardware security module alternatives pending patch availability; ensure all physical access attempts trigger alerts and investigation protocols.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Nshield 5c Firmware
View allEntrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a user with OS root access to a
The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow
A privilege escalation vulnerability (CVSS 7.2) that allows a physically proximate attacker with elevated privileges. Ri
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker
CVE-2025-59698 is a security vulnerability (CVSS 6.8) that allows a physically proximate attacker. Risk factors: public
CVE-2025-59694 is a security vulnerability (CVSS 6.8) that allows a physically proximate attacker. Risk factors: public
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow an attacker to gain access the
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker
CVE-2025-59696 is a security vulnerability (CVSS 3.2) that allows a physically proximate attacker. Risk factors: public
EUVD-2025-200272
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB