Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain physical access to T2000 unit
-
DeliveryConnect to exposed hardware debug/test interface
-
ExploitBypass ACL enforcement on interface
-
ExecutionIssue unauthorized commands
-
ImpactDisrupt device availability or modify device state
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Access control enforcement
MITRE ATT&CK
1 technique across 1 tactic: Defense Evasion The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Physical access to the T2000 hardware is the primary and mandatory prerequisite, confirmed by the CVSS 4.0 AV:P (Physical) attack vector. The debug or test interface must be physically accessible on the device - standard production units appear to leave this interface exposed. No authentication credentials are required to interact with the interface (PR:N), and no user interaction or network connectivity is needed. Exploitation is inherently limited to individuals who can physically reach the device. Devices installed in locked, access-controlled enclosures or server rooms with enforced visitor logging represent a significantly reduced exposure surface. There is no indication that this vulnerability is exploitable remotely or over any network interface. |
| Impact | The CVSS 4.0 score of 5.2 (Medium) accurately reflects the physical access constraint (AV:P), which substantially limits opportunistic or remote exploitation and rules out network-based mass attack campaigns. The high availability impact (VA:H) is the most operationally significant signal - in OT environments where T2000 units control HVAC, access, or facility systems, device disruption can cascade into safety or business continuity incidents. Low integrity impact (VI:L) indicates limited configuration modification is also possible. No EPSS data was provided, and the absence of a CISA KEV listing and any known public POC indicates this has not been observed in active exploitation at time of analysis. A notable discrepancy exists: the 'Information Disclosure' tag in the input conflicts with the CVSS 4.0 VC:N (no confidentiality impact to the vulnerable system) - whether data exposure is a realistic secondary outcome should be confirmed against the Johnson Controls vendor advisory. Overall, real-world risk is moderate, primarily relevant to facilities with weak physical security controls around deployed T2000 hardware rather than internet-exposed environments. |
| Exploit ScenarioDerived | An attacker with physical access - such as an authorized contractor, a social-engineered insider, or a physical intruder who bypasses building security - connects directly to the T2000's exposed debug or test interface port and issues commands that are not subject to normal ACL enforcement. This could disable the controller, disrupting HVAC or facility management functions, or allow limited modification of device state. No public exploit code is known, so exploitation currently requires knowledge of the debug interface protocol and physical hardware access. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Aug 27, 2026
Improper access control on the debug and test interface of the Johnson Controls T2000 building automation controller exposes restricted device functionality to anyone with physical access, requiring no authentication. Versions prior to 31.6 are affected, with the primary risk being high availability disruption of the device alongside limited integrity modification capability. No public exploit code or active exploitation has been identified at time of analysis, and a vendor-released patch is available.
RemediationAI
Upgrade T2000 firmware to version 31.6 or later, per the vendor patch availability confirmed by Johnson Controls and the EUVD-2026-67140 entry. Consult the Johnson Controls Trust Center advisory at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories for official upgrade procedures and release notes. As a compensating control prior to patching, implement physical access restrictions for all T2000 units: install locked enclosures, enforce visitor and contractor access logging, and restrict keycard or physical access to equipment rooms. If the device design permits disabling the debug interface port physically (e.g., via a jumper or enclosure modification), evaluate this option against ongoing maintenance requirements, as disabling it may impede legitimate diagnostic work. Conduct a physical security audit of all T2000 installations in sensitive facilities as an immediate interim step.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The T2000 is a Johnson Controls building automation controller deployed in HVAC and facility management environments, identified by CPE cpe:2.3:a:johnson_controls:t2000:*:*:*:*:*:*:*:*. The vulnerability involves a debug or test interface - likely a physical hardware port such as UART, serial, or a diagnostic connector - that lacks proper access control enforcement, allowing access to functionality not constrained by ACLs. No CWE is formally assigned, but the vulnerability class aligns with CWE-284 (Improper Access Control) and CWE-912 (Hidden Functionality), both common in embedded OT/IoT devices where diagnostic interfaces are designed for manufacturing or maintenance use but not adequately secured in production deployments. The CVSS 4.0 vector confirms physical proximity is required (AV:P) with no attack requirements beyond device access.
Know when T2000 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N
Physical access required per description and AV:P; debug interface requires no privileges; high availability impact but no confidentiality impact and unchanged scope.
Primary rating from Vendor (jci).
CVSS VectorVendor: jci
Lifecycle Timeline
1DescriptionCVE.org
Debug and Test Interface With Improper Access Control vulnerability in Johnson Controls T2000 allows Accessing Functionality Not Properly Constrained by ACLs.
This issue affects T2000: before 31.6.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
EUVD-2026-67140
GHSA-h5wr-2px2-58v4
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB