Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent/radio proximity to robot
-
DeliveryExtract hardcoded passwords from firmware or docs
-
ExploitAuthenticate to access control interface
-
ExecutionReconfigure robot and alter operation
-
ImpactFull compromise of EOD/recon robot
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Credential externalization
MITRE ATT&CK
2 techniques across 2 tactics: Persistence, Credential Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires (1) network/radio adjacency to a target PackBot or FirstLook robot running Aware2 ≤6.9.0.2 or ≤1.7.9 respectively - per CVSS AV:A, not open-internet reachability - and (2) knowledge of the built-in hardcoded passwords, which are obtainable by reading them from the device firmware image or from product documentation. No authentication is needed (PR:N) and no user interaction (UI:N); the credentials function against the affected software's access control by design, so any unpatched unit in the attacker's radio/network range is exploitable. The primary limiting factor is proximity and the specialized, access-controlled nature of the deployment base (defense/EOD operators), not any configuration prerequisite. |
| Impact | This is a genuine high-priority issue rather than an inflated CVSS score. CWE-798 (hardcoded credentials) combined with the CVSS 4.0 vector (AC:L/AT:N/PR:N/UI:N) means exploitation is trivial once an attacker is in range: no authentication, no special conditions, no user interaction, and full compromise of both the vulnerable system and subsequent systems (VC/VI/VA and SC/SI/SA all High), justifying the 9.4 critical rating. The one mitigating signal is the attack vector: CVSS 4.0 specifies AV:A (Adjacent), NOT network - this directly conflicts with the description's phrase 'remote unauthenticated attackers' and should be verified. Because PackBot/FirstLook are field-deployed robots typically controlled over wireless/radio links, 'adjacent' (radio/local-link proximity) is the more defensible reading, meaning an attacker must be within network/radio range rather than exploiting across the open internet. No EPSS score, no CISA KEV listing, and no public exploit code were provided; the Mandiant reference is a coordinated vulnerability disclosure, not a weaponized POC. Net: credible, easy-to-weaponize flaw with full impact, but real-world exposure is bounded by physical/radio proximity and the niche defense/EOD deployment base, not mass internet scanning. |
| Exploit ScenarioDerived | An attacker within radio/network range of a FLIR PackBot or FirstLook robot extracts the hardcoded passwords from the publicly obtainable firmware or product documentation, then authenticates to the robot's access control interface. With valid built-in credentials they take over the device - reading its state and reconfiguring the robot - without any legitimate authorization. No public exploit code is identified at time of analysis, but the credentials themselves are the exploit and require no development effort. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 01, 2026
Hardcoded credentials in Teledyne FLIR Aware2 let unauthenticated attackers within radio or network adjacency (CVSS AV:A) bypass the software's access control and read or reconfigure affected PackBot (Aware2 through 6.9.0.2) and FirstLook (Aware2 through 1.7.9) robots. Because the passwords are embedded in firmware images and reproduced in product documentation, anyone holding a unit image or manual can obtain them without bespoke exploit tooling; no authentication (PR:N) and no user interaction (UI:N) are required, and the assessed scope change (S:C) reflects full compromise of the robot platform. No public exploit code has been identified at time of analysis, but the design-level flaw (CWE-798) means the credentials themselves are the attack vector, and Mandiant's disclosure (MNDT-2026-0031) frames this as a genuine high-priority issue rather than an inflated CVSS score.
RemediationAI
No vendor-released patch version is identified in the available data, so the primary action is to contact Teledyne FLIR support for updated Aware2 firmware that addresses MNDT-2026-0031 for PackBot units running builds through 6.9.0.2 and FirstLook units running builds through 1.7.9, and to track the Mandiant advisory (https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2026/MNDT-2026-0031.md) for a fixed release; until a fix ships, treat the built-in credentials as compromised. Where Aware2 allows it, change or disable the hardcoded access-control passwords (trade-off: existing operator workflows, scripts and control software that reference the default credentials will stop working and must be re-provisioned). Restrict who can read firmware images and documentation that contain the passwords and strip credential content from field manuals and distribution packages (trade-off: reduced convenience for operators who rely on printed defaults). Enforce adjacency control - RF shielding or monitored, encrypted links between operator control units and robots, and segmentation that keeps robot command-and-control traffic out of shared or untrusted LANs (trade-off: reduced operational range and flexibility, which is operationally significant for EOD missions). Because exploitation needs only proximity plus a known password, add continuous detection for anomalous command sessions, unexpected pairing attempts and unexplained configuration changes on PackBot and FirstLook units as a necessary compensating detective control while no patch is available.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-798 (Use of Hardcoded Credentials): the Aware2 access-control layer authenticates operators against static passwords baked into the software/firmware and duplicated in printed documentation, rather than using per-device secrets or operator-provisioned credentials. The affected CPE is cpe:2.3:a:teledyne_flir:aware2, and ENISA EUVD-2026-91052 lists affected builds as Aware2 ≤1.7.9 (FirstLook) and ≤6.9.0.2 (PackBot); this is the software stack that operates Teledyne FLIR's PackBot and FirstLook unmanned ground vehicles used in defense, EOD and hazardous-response work. The exposure surface is the robot's command-and-control interface, reachable over the radio link or the local network joining robot and operator control unit, which is why both the submitted CVSS 4.0 score (9.4, AV:A/PR:N/UI:N) and the independent CVSS 3.1 assessment (AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H) rate it as adjacent rather than internet-reachable. With PR:N and UI:N, an attacker who already knows the documented password needs no credential and no social step; confidentiality, integrity and availability are all rated high, and the scope change reflects downstream impact on the physical robot platform. That matters because a UGV is a safety-critical asset with video, mobility and manipulation control, so 'reconfigure' means direct operational control of the device rather than a data-only breach. The only meaningful limiting factor is proximity plus the specialized, access-controlled nature of the deployment base.
Know when Aware2 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Hardcoded creds give unauthenticated adjacent access (AV:A/PR:N/AC:L); full read/reconfigure control and impact on the controlled robot beyond the auth component justify S:C and C/I/A:H.
Primary rating from Vendor (Mandiant).
CVSS VectorVendor: Mandiant
DescriptionCVE.org
Hardcoded passwords in the access control in Teledyne FLIR Aware2 versions through 6.9.0.2 (PackBot) and 1.7.9 (FirstLook) allows remote unauthenticated attackers to access and reconfigure Teledyne FLIR PackBot and FirstLook robots running this software via reading the passwords from the firmware or documentation.
Executive ViewAI
Teledyne FLIR's Aware2 control software, shipped with PackBot (through version 6.9.0.2) and FirstLook (through version 1.7.9) unmanned ground vehicles, contains hardcoded credentials that allow an unauthenticated attacker with radio or network adjacency to take full control of the robot platform. Because the passwords are embedded in firmware and reproduced in product documentation, the bar to exploitation is low and no detection signature or exploit tooling is required. Any organization fielding these robots - notably public safety bomb squads, hazardous materials teams, and defense units - must treat the affected units as potentially compromiseable assets whose availability and integrity cannot currently be assured by vendor remediation.
No vendor-released patch identified at time of analysis. Interim mitigations include: isolating affected robots and their Aware2 controllers on dedicated network segments with no path to enterprise or untrusted networks; disabling or physically securing wireless/radio interfaces when units are not in active use; restricting radio and network adjacency to vetted operators and controlling the physical operating perimeter; changing any credentials exposed in the configuration where the software permits it and validating that the change is not reverted by firmware; auditing controller logs for unauthorized access or reconfiguration; and escalating to Teledyne FLIR for interim vendor guidance or early access to a fix.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Unvalidated pathnames in the Teledyne FLIR Aware2 web interface let remote unauthenticated attackers read configuration
Cleartext transmission in the primary control endpoints of Teledyne FLIR Aware2 (all versions through 6.9.0.2) allows an
Unauthenticated attackers on the same adjacent network or RF segment can intercept, hijack, or modify cleartext UDP cont
Unauthenticated denial of service against Teledyne FLIR PackBot robots running the Aware2 web interface, where the reboo
Cleartext 802.11 session traffic between Teledyne FLIR Aware2 (versions through 6.9.0.2) and PackBot robots can be sniff
EUVD-2026-91052
GHSA-r959-63hv-grw3
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB