Skip to main content

Tenda CVE-2026-4493

| EUVDEUVD-2026-13754 HIGH
Stack-based Buffer Overflow (CWE-121)
2026-03-20 VulDB
7.4
CVSS 4.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Tenda A18 Pro admin interface
  2. Delivery
    Send crafted POST to /goform/setMacFilterCfg
  3. Exploit
    Inject oversized deviceList parameter
  4. Execution
    Overflow stack buffer in sub_423B50
  5. Impact
    Execute arbitrary code with router privileges

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires authenticated access (PR:L) to Tenda A18 Pro firmware version 02.03.02.28. Attacker must send a crafted request to /goform/setMacFilterCfg endpoint with malicious deviceList parameter to trigger stack-based buffer overflow in MAC Filtering Configuration function.

Impact

This vulnerability presents significant real-world risk with multiple concerning indicators. The CVSS score of 8.8 (High) reflects critical characteristics: network-accessible attack vector (AV:N), low attack complexity (AC:L), requires only low privileges (PR:L), no user interaction (UI:N), and full impact on confidentiality, integrity, and availability (C:H/I:H/A:H). The exploit maturity indicator shows proof-of-concept code exists (E:P), confirmed by the public GitHub repository containing working exploit code. The combination of authenticated remote exploitation capability, publicly available exploit code, and impact on consumer IoT infrastructure makes this a realistic threat. While low-privilege authentication is required, many consumer routers use default or weak credentials. The lack of remediation level information (RL:X) suggests no official patch may be available, further elevating risk. This should be considered a genuine priority for organizations and consumers using affected Tenda devices, particularly given the typical internet-facing deployment of routers.

Exploit ScenarioDerived

An attacker on the local network or with VPN access authenticates to the Tenda A18 Pro router's web interface using compromised, default, or brute-forced low-privilege credentials. They then craft a malicious HTTP request to /goform/setMacFilterCfg containing an oversized deviceList parameter designed to overflow the stack buffer in function sub_423B50. Using the publicly available proof-of-concept from GitHub (https://github.com/lilukun337/cve/issues/5) as a template, the attacker injects shellcode that executes with the privileges of the web server process, potentially gaining full control of the router to intercept traffic, pivot to internal networks, or establish persistent backdoor access.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 20, 2026

Stack-based buffer overflow in Tenda A18 Pro MAC filtering configuration allows remote authenticated attackers to achieve full system compromise through manipulation of the deviceList parameter. Public exploit code exists for this vulnerability, and no patch is currently available. The flaw impacts the /goform/setMacFilterCfg endpoint with a CVSS score of 8.8.

Earlier versions of this analysis (1)
v1 Mar 20, 2026 - 17:45 CVSS 8.8

A stack-based buffer overflow vulnerability exists in the MAC Filtering Configuration endpoint of Tenda A18 Pro router firmware version 02.03.02.28. An authenticated attacker with low-level privileges can exploit the deviceList parameter in the /goform/setMacFilterCfg endpoint via the sub_423B50 function to achieve remote code execution with high impact to confidentiality, integrity, and availability. A public proof-of-concept exploit is available on GitHub, significantly lowering the barrier to exploitation.

RemediationAI

Check the official Tenda website (https://www.tenda.com.cn/) and contact Tenda support for firmware updates addressing this vulnerability, as no specific patched version has been publicly announced based on available references. Until an official patch is available, implement network-level mitigations: disable remote administration access to the router's web interface, restrict management interface access to trusted internal IP addresses only, change default administrative credentials to strong unique passwords, and consider deploying the router behind additional network segmentation or firewall rules. Organizations should also disable MAC address filtering if not operationally required, as this removes the vulnerable attack surface entirely. Monitor VulDB tracking pages (https://vuldb.com/?id.352019) for updates on patch availability.

Affected VersionsENISA

A18 Pro 02.03.02.28

Affected Packages

euvd a18_pro no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability affects the Tenda A18 Pro wireless router (CPE: cpe:2.3:a:tenda:a18_pro) running firmware version 02.03.02.28. The issue is classified as CWE-121 (Stack-based Buffer Overflow), occurring in the MAC address filtering configuration module. When processing MAC address device lists through the web management interface endpoint /goform/setMacFilterCfg, the function sub_423B50 fails to properly validate input length before copying data to a fixed-size stack buffer. This classic memory corruption vulnerability allows an attacker to overwrite adjacent memory regions on the stack, potentially including return addresses and function pointers, leading to arbitrary code execution within the context of the router's web server process.

Know when Tenda gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

3
CVSS changed
Apr 22, 2026 - 21:37 NVD
8.8 (HIGH) 7.4 (HIGH)
PoC Detected
Mar 24, 2026 - 15:54 vuln.today
Public exploit code
CVE Published
Mar 20, 2026 - 17:32 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was determined in Tenda A18 Pro 02.03.02.28. The impacted element is the function sub_423B50 of the file /goform/setMacFilterCfg of the component MAC Filtering Configuration Endpoint. Executing a manipulation of the argument deviceList can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability (CVE-2026-4493) affects Tenda A18 Pro routers, allowing authenticated attackers to gain complete control of affected devices. Organizations using this router model face immediate risk of network compromise, data theft, and service disruption, with active public exploits already available.

Business Impact: Severe
Compensating Controls

Disable the MAC Filtering Configuration feature entirely if not operationally required; implement WAF rules to block POST requests to /goform/setMacFilterCfg endpoint; restrict administrative access to the router's web interface via network-level access controls (firewall rules, VPN-only access); enable detailed logging and alerting on all authentication attempts to the device; consider network segmentation to isolate the router from critical assets.

Threat Intelligence Overview

EPSS Score
0.0%
Top 86% exploitable
Exploit
POC
Public exploit code exists
Data Quality
7 sources
Confidence: High
EUVD NVD CVE.org EPSS Vulnrichment GitHub VulDB

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
Poc
System Exposure· derived
Open
Automatable
No
Human Impact
Very High
Technical Impact
Total

Priority Score

57
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +37
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Related Vulnerabilities in Tenda A18 Pro Buffer Overflow Vulnerabilities

View all 3

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy