Skip to main content

Siemens Industrial Edge CVE-2026-44414

| EUVDEUVD-2026-98378 MEDIUM
Path Traversal: '.../...//' (CWE-35)
2026-10-13 siemens GHSA-9xh9-64gc-w6jh
Authentication Bypass Siemens Industrial Edge Cloud Device Iecd Industrial Edge Device Kit Arm64 V1 10 Industrial Edge Device Kit Arm64 V1 11 Industrial Edge Device Kit Arm64 V1 12 Industrial Edge Device Kit Arm64 V1 13 Industrial Edge Device Kit Arm64 V1 14 Industrial Edge Device Kit Arm64 V1 15 Industrial Edge Device Kit Arm64 V1 16 Industrial Edge Device Kit Arm64 V1 17 Industrial Edge Device Kit Arm64 V1 18 Industrial Edge Device Kit Arm64 V1 19 Industrial Edge Device Kit Arm64 V1 20 Industrial Edge Device Kit Arm64 V1 21 Industrial Edge Device Kit Arm64 V1 22 Industrial Edge Device Kit Arm64 V1 23 Industrial Edge Device Kit Arm64 V1 24 Industrial Edge Device Kit Arm64 V1 25 Industrial Edge Device Kit Arm64 V1 26 Industrial Edge Device Kit Arm64 V1 27 Industrial Edge Device Kit Arm64 V1 28 Industrial Edge Device Kit Arm64 V1 5 Industrial Edge Device Kit Arm64 V1 6 Industrial Edge Device Kit Arm64 V1 7 Industrial Edge Device Kit Arm64 V1 8 Industrial Edge Device Kit Arm64 V1 9 Industrial Edge Device Kit X86 64 V1 10 Industrial Edge Device Kit X86 64 V1 11 Industrial Edge Device Kit X86 64 V1 12 Industrial Edge Device Kit X86 64 V1 13 Industrial Edge Device Kit X86 64 V1 14 Industrial Edge Device Kit X86 64 V1 15 Industrial Edge Device Kit X86 64 V1 16 Industrial Edge Device Kit X86 64 V1 17 Industrial Edge Device Kit X86 64 V1 18 Industrial Edge Device Kit X86 64 V1 19 Industrial Edge Device Kit X86 64 V1 20 Industrial Edge Device Kit X86 64 V1 21 Industrial Edge Device Kit X86 64 V1 22 Industrial Edge Device Kit X86 64 V1 23 Industrial Edge Device Kit X86 64 V1 24 Industrial Edge Device Kit X86 64 V1 25 Industrial Edge Device Kit X86 64 V1 26 Industrial Edge Device Kit X86 64 V1 27 Industrial Edge Device Kit X86 64 V1 28 Industrial Edge Device Kit X86 64 V1 5 Industrial Edge Device Kit X86 64 V1 6 Industrial Edge Device Kit X86 64 V1 7 Industrial Edge Device Kit X86 64 V1 8 Industrial Edge Device Kit X86 64 V1 9 Industrial Edge Own Device Ieod Industrial Edge Virtual Device Ievd Scalance Lpe9413 Scalance Lpe9433 Simatic Iot2050 Advanced Ied Simatic Iot2050 Sm Ied Simatic Ipc Bx 21A Industrial Edge Device Simatic Ipc Bx 39A Industrial Edge Device Simatic Ipc Bx 59A Industrial Edge Device Simatic Ipc127E Industrial Edge Device Simatic Ipc227E Industrial Edge Device Simatic Ipc227G Industrial Edge Device Simatic Ipc427E Industrial Edge Device Simatic Ipc847E Industrial Edge Device
6.9
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Industrial Edge device interface
  2. Exploit
    Request restricted internal API/path
  3. Execution
    Retrieve sensitive internal information
  4. Impact
    Leverage data for broader system access

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path traversal prevention
Exploitation Conditions

Exploitation requires an authenticated, network-reachable session to the affected Siemens Industrial Edge device's management interface/internal APIs; the device fails to properly restrict access to internal APIs and file paths for authenticated users (CWE-35 path traversal/relative path handling), so a logged-in user can reach endpoints beyond their intended authorization and read sensitive internal information. Limiting factors: valid authentication is mandatory (the vendor rates this PR:H, implying a high-privilege account, though the description's wording suggests any authenticated user may suffice - verify with Siemens), no user interaction is needed (UI:N), and the attacker must have network access to the device's exposed interface, which in OT environments is typically segmented behind industrial network boundaries.

Impact

This is a moderate-severity information-disclosure issue (CVSS 6.8) rather than a top-tier priority. The vendor CVSS vector CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N indicates network-reachable, low-complexity exploitation but with a meaningful barrier: privileges are required (PR:H), so an attacker must already hold a valid - and per Siemens, high-privileged - authenticated session. Scope is changed (S:C) and confidentiality impact is high (C:H), reflecting that leaked internal API/path data crosses a trust boundary and could facilitate deeper system access; integrity and availability are unaffected (I:N/A:N). There is NO EPSS score, NO CISA KEV listing, and NO public proof-of-concept in the provided data, so there is no public exploit identified at time of analysis and no evidence of active exploitation - the risk is driven by severity ratings, not by observed in-the-wild activity. CONFLICT TO VERIFY: the vendor assigned PR:H, but the description states access is improperly restricted 'for authenticated users' generally and refers only to 'an authenticated remote attacker,' which implies any authenticated user (PR:L) may suffice - if so, the real-world barrier is lower than the vendor vector suggests; verify the required privilege level with Siemens. Overall this is a credible but secondary-priority flaw: exploitation presupposes existing authenticated access to an OT edge device, and the worst-case outcome (information that 'could be leveraged to facilitate unauthorized access') is a potential escalation path, not a confirmed direct compromise.

Exploit ScenarioDerived

An attacker who has obtained valid credentials (or hijacked an authenticated session) to a Siemens Industrial Edge device sends crafted requests to internal API endpoints or file paths that should be restricted, retrieving sensitive internal information. Because the CVSS vector is AV:N/AC:L, this requires only network reachability to the management interface and low attack complexity, with no user interaction. No public exploit code is identified at time of analysis, so exploitation would rely on a custom request against the authorization/path-handling flaw (CWE-35).

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 13, 2026

Improper restrictions on internal APIs and file paths in Siemens Industrial Edge deployments - the Industrial Edge Device Kits for arm64 and x86-64 from V1.5 through V1.28, Industrial Edge Cloud Device (IECD), Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413/LPE9433, SIMATIC IoT2050 variants and the SIMATIC IPC BX-21A/BX-39A/BX-59A, IPC127E, IPC227E, IPC227G, IPC427E and IPC847E edge devices - allow an authenticated remote user to reach internal endpoints and resources beyond their intended authorization and read sensitive internal information, which in the worst case can be leveraged to facilitate unauthorized access to the system. The vendor score is CVSS 6.8 (AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N), a confidentiality-only, scope-changing information-disclosure issue; the independent assessment reproduces the same vector but rates the privilege requirement as PR:L, so treating any authenticated user as a potential attacker is the safer assumption pending Siemens clarification. Exploitation requires network reachability to the device's management/internal API surface plus valid credentials, which in typical OT architectures confines risk to segmented industrial networks; no public exploit code and no confirmed active exploitation (no CISA KEV listing) were identified at time of analysis, making this a moderate-priority hardening item rather than an emergency patch.

RemediationAI

Patch status is not confirmed from the available data - no exact fixed version is given for this CVE, so the first action is to pull the two Siemens advisories (SSA-377139 at https://cert-portal.siemens.com/productcert/html/ssa-377139.html and SSA-832641 at https://cert-portal.siemens.com/productcert/html/ssa-832641.html) and apply the vendor-released update for each affected product once it is published, since the fix is expected to tighten authorization checks on the internal API and path-handling layer shared across the arm64/x86-64 Device Kits, IECD, IEOD, IEVD, SCALANCE LPE9413/LPE9433 and the SIMATIC IoT2050 and IPC edge families. Until a fixed release is installed, treat every authenticated account on these devices as potentially able to read internal data and apply compensating controls with the following trade-offs: (1) restrict network access to the Industrial Edge management interface and internal APIs to a dedicated, firewalled engineering VLAN, which sharply reduces the attacker pool but blocks legitimate remote administration until access lists and jump hosts are updated; (2) enforce least privilege and strict account inventory - remove or disable unused and service accounts, and lower every account that does not strictly need administrative rights, since the vendor scores the flaw PR:H while our assessment assumes PR:L may suffice, so assuming the lowest privilege is prudent (this can break automation that relies on broad API rights); (3) enable and centralize audit logging on API requests, watching for traversal-style sequences and unexpected requests to internal endpoints, accepting the extra log volume and storage cost; (4) rotate any credentials, tokens or certificates that may have been exposed through the internal information disclosure if unauthorized API access is suspected, at the cost of a short maintenance interruption; and (5) for installations that cannot isolate the management interface, consider temporarily disabling non-essential internal API or web-management features per Siemens guidance, which removes the attack surface but degrades management and monitoring capability. No public exploit code or confirmed active exploitation was identified at time of analysis, so these actions can be scheduled as part of normal OT patch and segmentation cycles rather than an emergency response, provided the device is not internet-exposed.

Affected VersionsENISA

Industrial Edge Virtual Device (IEVD) 0 <V1.28.1
Industrial Edge Device Kit - arm64 V1.12 0 <*
Industrial Edge Device Kit - arm64 V1.9 0 <*
Industrial Edge Device Kit - x86-64 V1.21 0 <*
SIMATIC IPC127E Industrial Edge Device 0 <V3.2.0-17
Industrial Edge Device Kit - arm64 V1.8 0 <*
Industrial Edge Device Kit - x86-64 V1.25 0 <*
Industrial Edge Device Kit - arm64 V1.19 0 <*
Industrial Edge Device Kit - x86-64 V1.19 0 <*
Industrial Edge Device Kit - x86-64 V1.26 0 <V1.26.2-1
Industrial Edge Device Kit - arm64 V1.15 0 <*
Industrial Edge Device Kit - arm64 V1.5 0 <*
Industrial Edge Own Device (IEOD) 0 <V1.28.1
Industrial Edge Device Kit - arm64 V1.10 0 <*
Industrial Edge Device Kit - x86-64 V1.27 0 <V1.27.1-1
SCALANCE LPE9413 0 <*
SIMATIC IPC847E Industrial Edge Device 0 <V3.2.0-17
SIMATIC IoT2050 SM IED 0 <V1.28.1-2
Industrial Edge Device Kit - arm64 V1.14 0 <*
Industrial Edge Device Kit - x86-64 V1.22 0 <*
Industrial Edge Device Kit - x86-64 V1.17 0 <*
Industrial Edge Device Kit - arm64 V1.23 0 <*
Industrial Edge Device Kit - x86-64 V1.16 0 <*
Industrial Edge Device Kit - arm64 V1.21 0 <*
Industrial Edge Device Kit - arm64 V1.18 0 <*
Industrial Edge Device Kit - x86-64 V1.15 0 <*
Industrial Edge Device Kit - x86-64 V1.23 0 <*
Industrial Edge Device Kit - x86-64 V1.24 0 <*
Industrial Edge Device Kit - x86-64 V1.12 0 <*
Industrial Edge Device Kit - arm64 V1.24 0 <*
Industrial Edge Device Kit - x86-64 V1.8 0 <*
SIMATIC IPC BX-21A Industrial Edge Device 0 <V1.28.1-2
Industrial Edge Device Kit - x86-64 V1.10 0 <*
Industrial Edge Device Kit - x86-64 V1.7 0 <*
Industrial Edge Device Kit - arm64 V1.16 0 <*
SCALANCE LPE9433 0 <*
Industrial Edge Device Kit - arm64 V1.6 0 <*
Industrial Edge Device Kit - x86-64 V1.6 0 <*
Industrial Edge Device Kit - x86-64 V1.13 0 <*
Industrial Edge Device Kit - arm64 V1.27 0 <V1.27.1-1
SIMATIC IoT2050 Advanced IED 0 <V1.28.1-2
Industrial Edge Cloud Device (IECD) 0 <V1.28.1
Industrial Edge Device Kit - x86-64 V1.5 0 <*
SIMATIC IPC227E Industrial Edge Device 0 <V3.2.0-17
SIMATIC IPC BX-39A Industrial Edge Device 0 <V3.2.0-17
Industrial Edge Device Kit - arm64 V1.7 0 <*
Industrial Edge Device Kit - x86-64 V1.11 0 <*
SIMATIC IPC227G Industrial Edge Device 0 <V3.2.0-17
Industrial Edge Device Kit - arm64 V1.20 0 <*
SIMATIC IPC BX-59A Industrial Edge Device 0 <V3.2.0-17
Industrial Edge Device Kit - x86-64 V1.9 0 <*
Industrial Edge Device Kit - x86-64 V1.18 0 <*
Industrial Edge Device Kit - arm64 V1.26 0 <V1.26.2-1
Industrial Edge Device Kit - arm64 V1.28 0 <V1.28.0-6
Industrial Edge Device Kit - arm64 V1.11 0 <*
Industrial Edge Device Kit - x86-64 V1.20 0 <*
Industrial Edge Device Kit - arm64 V1.17 0 <*
Industrial Edge Device Kit - x86-64 V1.14 0 <*
Industrial Edge Device Kit - arm64 V1.25 0 <*
Industrial Edge Device Kit - arm64 V1.13 0 <*
Industrial Edge Device Kit - arm64 V1.22 0 <*
SIMATIC IPC427E Industrial Edge Device 0 <V3.2.0-17
Industrial Edge Device Kit - x86-64 V1.28 0 <V1.28.0-6

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is tracked as CWE-35 (path traversal: '.../...//'), a class of flaw where user-influenced path or endpoint input is not canonicalized or normalized before being resolved, allowing traversal outside the intended directory or API namespace. Here the failure is described as improper restriction of access to internal APIs and paths for authenticated users: the device exposes an authenticated management surface, but once a session exists the authorization checks on internal API routes and file paths are insufficient, so relative-path or traversal-style requests can reach resources the account was never meant to see. The CVSS vector CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N confirms the profile - network attack vector, low complexity, no user interaction, high confidentiality impact, no integrity or availability impact, and Scope:Changed because the compromised component (the API/authorization layer) yields access to resources in a different security scope (internal data, configuration or credential material). Siemens rates the privilege requirement as High (PR:H), i.e. an administrative-class account, whereas our independent assessment scored PR:L, meaning a lower-privileged authenticated user may be sufficient; because the CPE inventory spans both arm64 and x86-64 Industrial Edge Device Kits across many minor releases plus hardware appliances (IECD, IEOD, IEVD, SCALANCE LPE9413 with order number 6GK5998-3GS01-2AC2, SCALANCE LPE9433 with 6GK5998-3GS11-2AC2, SIMATIC IoT2050 Advanced IED 6ES7647-0BW00-1YA2, SIMATIC IoT2050 SM IED 6ES7647-0CW00-1AA2, and the SIMATIC IPC edge families), the flaw most likely lives in shared Industrial Edge management/runtime services common to the whole product line rather than in a single appliance firmware image. Information disclosed in this class of bug can include internal API responses, file-system contents, configuration, tokens or credential material, which is why the CIA impact is confidentiality-high even though no direct code execution or write primitive is claimed; the token 'Authentication Bypass' in the source tags reflects the post-authentication authorization-bypass effect rather than a pre-auth bypass of the login itself.

Know when Scalance Lpe9413 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 6.9 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N
vuln.today AI 7.7 HIGH

Network-reachable, low-complexity authorized access; description implies any authenticated user suffices (PR:L vs vendor PR:H); crosses trust boundary (S:C) with information disclosure only, so C:H/I:N/A:N.

3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
Present
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
None
Vulnerable system: Availability
None
Subsequent system: Confidentiality
High
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

1
CVSS changed
Oct 13, 2026 - 10:22 NVD
6.8 (MEDIUM) 6.9 (MEDIUM)

DescriptionCVE.org

A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.

Threat Intelligence Overview

EPSS Score
0.5%
Top 62% exploitable
Prevalence
Low
Siemens industrial/OT edge appliances, manufacturing-specific deployment footprint
Social Media
1
Sightings
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.5%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

34
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +34
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy