Skip to main content

Phoenix Contact CHARX CVE-2026-44095

| EUVDEUVD-2026-51030 HIGH
OS Command Injection (CWE-78)
2026-07-30 info@cert.vde.com GHSA-mw8x-6p3j-j9fh
8.5
CVSS 4.0 · Vendor: cert
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate as low-privileged local user
  2. Delivery
    Invoke network-configuration script
  3. Exploit
    Inject OS command via unsanitized input
  4. Execution
    Command executes as root
  5. Impact
    Full device compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires an existing low-privileged authenticated local account on the device (CVSS PR:L, AV:L) and access to the vulnerable network-configuration script that runs with root privileges; the attacker supplies crafted input to that script to inject OS commands. What limits exploitation: the attacker must already have local, authenticated access to the controller (no remote or unauthenticated path per the AV:L/PR:L vector), and only firmware versions 1.0.0 through those before 1.9.1 on CHARX SEC-3000/3050/3100/3150 are affected. No user interaction is required (UI:N).

Impact

The CVSS 4.0 vector (AV:L/AC:L/AT:N/PR:L/UI:N, VC:H/VI:H/VA:H) describes a locally exploitable, low-complexity flaw requiring existing low-level authentication but no user interaction, with total loss of confidentiality, integrity, and availability of the device - a coherent and self-consistent signal set for a local privilege-escalation bug. No EPSS score, POC reference, or KEV entry was provided, so real-world exploitation likelihood cannot be quantified; the local attack vector inherently limits mass, remote exploitation. The practical risk is elevated for any deployment where multiple users, remote-management sessions, or lower-trust processes can reach a local shell on the controller, since escalation to root is then straightforward; for physically isolated single-operator installs the exposure is lower. There is no conflict between the CVSS vector and the description - both point to local, authenticated privilege escalation.

Exploit ScenarioDerived

An attacker who already holds a low-privileged local account on a CHARX SEC controller (for example, a limited operator login or a foothold from another lower-trust process) invokes the network-configuration script with crafted input containing shell metacharacters. The script executes the injected commands as root, giving the attacker a root shell and complete control of the charging controller. No public exploit code was identified, but the low attack complexity makes weaponization straightforward for someone with local access.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Jul 30, 2026

Local privilege escalation in Phoenix Contact CHARX SEC-3000/3050/3100/3150 EV charging controllers (firmware 1.0.0 through versions before 1.9.1) lets a low-privileged local user inject OS commands through a network-configuration script and gain root, yielding full device compromise. The flaw is a classic CWE-78 command injection reachable by any authenticated local account (CVSS 4.0 8.5). No public exploit identified at time of analysis, and it is not listed in CISA KEV.

RemediationAI

Vendor-released patch: update affected CHARX SEC-3000/3050/3100/3150 controllers to firmware 1.9.1 or later, which is the first fixed release per the CERT@VDE advisory VDE-2026-008 (https://www.certvde.com/en/advisories/VDE-2026-008/). Until the update can be applied, reduce exposure by restricting who can obtain a local/authenticated session on the controller - limit and audit local user accounts, disable or tightly control any remote-shell or remote-management access to the device, and place the charging controllers on a segmented management network reachable only by trusted operators; the trade-off is reduced remote administrability and added operational friction. Because the flaw lives in a root-privileged network-configuration script, avoid delegating network-configuration functions to low-privileged users where the platform allows it. Confirm the exact fixed version and any model-specific notes against the vendor advisory before deployment.

Affected VersionsENISA

CHARX SEC-3150 1.0.0 <1.9.1
CHARX SEC-3100 1.0.0 <1.9.1
CHARX SEC-3000 1.0.0 <1.9.1
CHARX SEC-3050 1.0.0 <1.9.1

Affected Packages

euvd charx_sec_3000 fix: 1.9.1
euvd charx_sec_3050 fix: 1.9.1
euvd charx_sec_3100 fix: 1.9.1
euvd charx_sec_3150 fix: 1.9.1

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 4 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected devices are Phoenix Contact CHARX SEC series charge controllers - embedded Linux-based control units for AC/DC electric-vehicle charging infrastructure. The root cause is CWE-78 (Improper Neutralization of Special Elements used in an OS Command), where a helper script responsible for network configuration passes attacker-influenced input into a shell context without proper sanitization. Because the script runs with elevated (root) privileges, injected shell metacharacters or arguments are executed as root. The EUVD-listed CPE-equivalent products are CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 across firmware 1.0.0 up to (not including) 1.9.1.

Know when the next one hits your stack

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (cert) PRIMARY 8.5 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.8 HIGH

Requires an existing low-privileged local account to abuse a root-run config script, so AV:L and PR:L with AC:L and no UI; command execution as root gives full C/I/A loss.

3.1 AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (cert).

CVSS VectorVendor: cert

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Jul 30, 2026 - 08:03 EUVD
CVE Published
Jul 30, 2026 - 07:16 cve.org
HIGH 8.5

DescriptionCVE.org

A privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.

Executive ViewAI

Why It Matters

Phoenix Contact EV charging controllers (CHARX SEC-3000/3050/3100/3150 models running firmware before 1.9.1) are vulnerable to privilege escalation attacks that allow any local account holder to seize full administrative control, potentially enabling charging station manipulation, credential theft, or network compromise. This exposure is particularly concerning in multi-user environments where contractors or administrative staff have system access. While no public exploit identified at time of analysis, the High severity rating (CVSS 8.5) warrants immediate patching.

Business Impact: High
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
0.2%
Top 86% exploitable
Prevalence
Low
niche EV-charging controller hardware, industry-specific deployment
Social Media
1
Sightings
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Small
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

42
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.