Skip to main content

Tenda CVE-2026-4254

| EUVDEUVD-2026-12488 CRITICAL
Buffer Overflow (CWE-119)
2026-03-16 cna@vuldb.com
9.8
CVSS 3.1 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Send crafted HTTP request to /goform/SysToolChangePwd
  2. Exploit
    Overflow local_2c parameter in doSystemCmd
  3. Execution
    Overwrite stack memory
  4. Impact
    Execute arbitrary code as root

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Tenda AC8 router firmware version 16.03.50.11 or earlier with HTTP endpoint /goform/SysToolChangePwd accessible. No authentication required for vulnerable endpoint.

Impact

This vulnerability presents an extremely high real-world risk based on multiple factors: the CVSS 3.1 score of 9.8 indicates critical severity with network-based attack vector (AV:N), low complexity (AC:L), no privileges required (PR:N), and no user interaction needed (UI:N). The availability of a public proof-of-concept exploit significantly increases the likelihood of exploitation. While no EPSS score or KEV listing is mentioned in the provided data, the combination of unauthenticated remote exploitation, public exploit code, and the widespread deployment of consumer routers makes this a priority for immediate remediation. The technical impact is severe as successful exploitation grants full device control, potentially allowing attackers to intercept network traffic, modify DNS settings, or use the device as a pivot point for further attacks.

Exploit ScenarioDerived

An attacker can scan for exposed Tenda AC8 routers on the internet and send a specially crafted HTTP request to the /goform/SysToolChangePwd endpoint containing an oversized payload in the local_2c parameter. This triggers a buffer overflow that overwrites the stack, allowing the attacker to execute arbitrary code with the privileges of the web server process, typically resulting in full router compromise. The publicly available proof-of-concept at https://github.com/digitalandrew/tenda_ac8_v5/blob/main/CVE_Report_Tenda_AC8_SysToolChangePwd_BOF.md demonstrates the exploitation technique.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 16, 2026

Remote code execution in Tenda AC8 firmware versions up to 16.03.50.11 results from a stack-based buffer overflow in the HTTP endpoint handling password change requests. An unauthenticated attacker can exploit this vulnerability over the network to execute arbitrary commands with full system privileges. Public exploit code exists for this vulnerability and no patch is currently available.

Earlier versions of this analysis (1)
v1 Mar 16, 2026 - 18:30 CVSS 9.8

A stack-based buffer overflow vulnerability exists in Tenda AC8 routers running firmware version 16.03.50.11 and earlier, affecting the password change functionality accessible via the HTTP endpoint /goform/SysToolChangePwd. The vulnerability allows remote attackers without authentication to achieve complete system compromise with high impact to confidentiality, integrity, and availability. A public proof-of-concept exploit is available on GitHub, making this vulnerability particularly dangerous for exposed devices.

RemediationAI

No patch or fixed firmware version has been identified in the available intelligence sources. Given the critical nature and public exploit availability, affected users should immediately disable remote management features and restrict administrative interface access to trusted local network segments only. Consider replacing the affected Tenda AC8 router with a device from a vendor with active security support if no patch becomes available. Monitor the vendor website at https://www.tenda.com.cn/ and the vulnerability references at https://vuldb.com/?id.351212 for updates on patch availability.

Affected VersionsENISA

AC8 16.03.50.9
AC8 16.03.50.4
AC8 16.03.50.1
AC8 16.03.50.10
AC8 16.03.50.6
AC8 16.03.50.11
AC8 16.03.50.2
AC8 16.03.50.8
AC8 16.03.50.3
AC8 16.03.50.5
AC8 16.03.50.7
AC8 16.03.50.0

Affected Packages

euvd ac8 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability resides in the doSystemCmd function that processes HTTP requests to the /goform/SysToolChangePwd endpoint on Tenda AC8 wireless routers. The flaw is classified as CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer), a classic buffer overflow condition where user-supplied input to the local_2c argument is not properly validated before being copied to a fixed-size stack buffer. This allows attackers to overwrite adjacent memory locations on the stack, potentially including the return address, enabling arbitrary code execution. The affected Tenda AC8 is a consumer-grade wireless router commonly used in home and small office environments.

Know when Tenda gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

A weakness has been identified in Tenda AC8 up to 16.03.50.11. This vulnerability affects the function doSystemCmd of the file /goform/SysToolChangePwd of the component HTTP Endpoint. This manipulation of the argument local_2c causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability affects Tenda AC8 routers up to firmware version 16.03.50.11, allowing unauthenticated attackers to execute arbitrary commands. Organizations using this router model face immediate risk of network compromise, data exfiltration, and potential lateral movement into connected systems, with no vendor patch currently available.

Business Impact: Severe
Compensating Controls

Implement Web Application Firewall (WAF) rules to block all requests to /goform/SysToolChangePwd endpoint; restrict HTTP/HTTPS access to router management interface via network segmentation and IP whitelisting; disable remote management features if not required; deploy network intrusion detection/prevention systems (IDS/IPS) signatures targeting this CVE; monitor router access logs for suspicious activity; implement VPN-only access to router administration; consider disabling the affected SysToolChangePwd functionality if alternative management methods exist.

Threat Intelligence Overview

EPSS Score
0.0%
Top 86% exploitable
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Very High

Priority Score

49
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy