Skip to main content

Tenda CVE-2026-3973

HIGH
Buffer Overflow (CWE-119)
2026-03-12 cna@vuldb.com
7.4
CVSS 4.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Tenda W3 web interface
  2. Delivery
    Send POST request to /goform/setAutoPing
  3. Exploit
    Inject oversized payload into ping1/ping2 parameter
  4. Execution
    Overflow stack buffer
  5. Impact
    Execute arbitrary code

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Tenda W3 firmware version 1.0.0.3(2204) with web management interface accessible; requires valid login credentials for POST Parameter Handler on /goform/setAutoPing endpoint; formSetAutoPing function must process user-supplied ping1/ping2 arguments without length validation

Impact

CVSS 8.8 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network.

Exploit ScenarioDerived

A remote attacker could exploit this vulnerability to compromise the affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Stack-based buffer overflow in Tenda W3 firmware version 1.0.0.3(2204) allows authenticated remote attackers to achieve complete system compromise through malicious ping parameters sent to the /goform/setAutoPing endpoint. Public exploit code is available for this vulnerability, increasing the risk of active exploitation. No patch is currently available, leaving affected devices exposed without mitigation options.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 19:57 CVSS 7.4

A vulnerability was determined in Tenda W3 1.0.0.3(2204). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component POST Parameter Handler. [CVSS 8.8 HIGH]

RemediationAI

Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-119 (Buffer Overflow). A vulnerability was determined in Tenda W3 1.0.0.3(2204). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component POST Parameter Handler. This manipulation of the argument ping1/ping2 causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Know when Tenda gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability was determined in Tenda W3 1.0.0.3(2204). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component POST Parameter Handler. This manipulation of the argument ping1/ping2 causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability exists in Tenda W3 wireless devices (version 1.0.0.3) affecting the auto-ping configuration function. Organizations using this device model face potential unauthorized access and network compromise, with no patch currently available from the vendor.

Business Impact: High
Compensating Controls

Implement network segmentation to restrict administrative access to affected Tenda W3 devices; disable the auto-ping feature if operationally acceptable; deploy WAF rules to block POST requests to /goform/setAutoPing; configure IDS/IPS signatures to detect exploitation attempts; restrict device management to VPN/bastion hosts only; monitor for suspicious device behavior and unauthorized configuration changes.

Threat Intelligence Overview

EPSS Score
0.1%
Top 75% exploitable
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

37
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +37
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:w3_firmware:1.0.0.3\(2204\):*:*:*:*:*:*:*

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy