Skip to main content

Fh1202 Firmware CVE-2026-3808

HIGH
Buffer Overflow (CWE-119)
2026-03-09 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Tenda FH1202 device
  2. Delivery
    Send malicious POST request to /goform/webtypelibrary
  3. Exploit
    Craft oversized webSiteId parameter
  4. Execution
    Trigger stack buffer overflow
  5. Impact
    Execute arbitrary code as root

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Tenda FH1202 firmware version 1.2.0.14(408) with formWebTypeLibrary function accessible at /goform/webtypelibrary endpoint. Attacker requires valid login credentials to the device web interface (PR:L). Stack-based buffer overflow triggered via webSiteId parameter manipulation.

Impact

CVSS 8.8 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network. Public exploit/POC available.

Exploit ScenarioDerived

A remote attacker could exploit this flaw, stack-based buffer overflow.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Stack-based buffer overflow in Tenda FH1202 firmware version 1.2.0.14(408) allows remote authenticated attackers to achieve full system compromise through manipulation of the webSiteId parameter in the /goform/webtypelibrary function. Public exploit code exists for this vulnerability, and no patch is currently available. The high CVSS score of 8.8 reflects the potential for complete confidentiality, integrity, and availability impact.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 21:56 CVSS 8.8

A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. [CVSS 8.8 HIGH]

RemediationAI

Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-119 (Buffer Overflow). Affects Fh1202 Firmware. A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Know when Fh1202 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Mar 09, 2026 - 15:30 vuln.today
Public exploit code
CVE Published
Mar 09, 2026 - 08:16 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Executive ViewAI

Why It Matters

A critical vulnerability in Tenda FH1202 wireless routers (CVE-2026-3808) allows attackers to execute unauthorized actions through a web interface function, with public exploit code now available. Organizations using this device model are at immediate risk of network compromise, unauthorized access, and potential lateral movement into connected systems.

Business Impact: High
Compensating Controls

Implement WAF rules blocking POST/GET requests to /goform/webtypelibrary endpoint; restrict administrative web interface access via firewall rules to trusted IP ranges only; disable remote management features on affected devices; segment router management traffic on dedicated VLAN; enable detailed logging on network perimeter devices; monitor for exploitation attempts; consider replacing with alternative vendor devices if patch timeline is uncertain.

Threat Intelligence Overview

EPSS Score
0.1%
Top 75% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*
CVE-2024-30589 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat fu

CVE-2024-30587 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo functi

CVE-2024-30584 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter of the formWifiBasicSet functio

CVE-2024-30596 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the formSetDeviceName functi

CVE-2024-30593 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName parameter of the formSetDeviceN

CVE-2024-30595 CRITICAL POC
9.8 Mar 28

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter functio

CVE-2023-38939 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the f

CVE-2023-38938 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi

CVE-2023-38932 CRITICAL POC
9.8 Aug 07

Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi

CVE-2023-37723 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37722 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

CVE-2023-37721 CRITICAL POC
9.8 Jul 14

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy