Fh1202 Firmware
CVE-2026-3808
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate to Tenda FH1202 device
-
DeliverySend malicious POST request to /goform/webtypelibrary
-
ExploitCraft oversized webSiteId parameter
-
ExecutionTrigger stack buffer overflow
-
ImpactExecute arbitrary code as root
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Tenda FH1202 firmware version 1.2.0.14(408) with formWebTypeLibrary function accessible at /goform/webtypelibrary endpoint. Attacker requires valid login credentials to the device web interface (PR:L). Stack-based buffer overflow triggered via webSiteId parameter manipulation. |
| Impact | CVSS 8.8 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network. Public exploit/POC available. |
| Exploit ScenarioDerived | A remote attacker could exploit this flaw, stack-based buffer overflow. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 12, 2026
Stack-based buffer overflow in Tenda FH1202 firmware version 1.2.0.14(408) allows remote authenticated attackers to achieve full system compromise through manipulation of the webSiteId parameter in the /goform/webtypelibrary function. Public exploit code exists for this vulnerability, and no patch is currently available. The high CVSS score of 8.8 reflects the potential for complete confidentiality, integrity, and availability impact.
Earlier versions of this analysis (1)
A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. [CVSS 8.8 HIGH]
RemediationAI
Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Classified as CWE-119 (Buffer Overflow). Affects Fh1202 Firmware. A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Know when Fh1202 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Executive ViewAI
A critical vulnerability in Tenda FH1202 wireless routers (CVE-2026-3808) allows attackers to execute unauthorized actions through a web interface function, with public exploit code now available. Organizations using this device model are at immediate risk of network compromise, unauthorized access, and potential lateral movement into connected systems.
Implement WAF rules blocking POST/GET requests to /goform/webtypelibrary endpoint; restrict administrative web interface access via firewall rules to trusted IP ranges only; disable remote management features on affected devices; segment router management traffic on dedicated VLAN; enable detailed logging on network perimeter devices; monitor for exploitation attempts; consider replacing with alternative vendor devices if patch timeline is uncertain.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Affected Products (CPE)CVE.org
Related Vulnerabilities in Tenda FH1202 Stack Buffer Overflow Issues
View all 5More in Fh1202 Firmware
View allTenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat fu
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo functi
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter of the formWifiBasicSet functio
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the formSetDeviceName functi
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName parameter of the formSetDeviceN
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter functio
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the f
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow vi
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB