Skip to main content

Sfx2100 Firmware CVE-2026-29124

HIGH
Improper Privilege Management (CWE-269)
2026-03-05 b7efe717-a805-47cf-8e9a-921fca0ce0ce
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 12, 2026 - 22:06 vuln.today
PoC Detected
Mar 11, 2026 - 18:35 vuln.today
Public exploit code
CVE Published
Mar 05, 2026 - 02:16 nvd
HIGH 7.8

DescriptionCVE.org

Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the monitor user to root

AnalysisAI

Sfx2100 Satellite Receiver firmware contains multiple SUID root binaries in predictable locations that allow local privilege escalation from the monitor user to root. Public exploit code exists for this vulnerability, enabling any local user with monitor privileges to gain complete system control. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Login as monitor user
Exploit
Locate SUID root binary in /home/monitor/terminal
Execution
Execute binary with crafted arguments
Impact
Escalate privileges to root

Vulnerability AssessmentAI

Exploitation Local access as 'monitor' user on IDC SFX2100 Satellite Receiver with SUID root binaries present in /home/monitor/terminal, /home/monitor/kore-terminal, or /home/monitor/IDE-DPack/terminal-dpack directories. Additional conditions and limiting factors are described in the full assessment.
Risk Assessment CVSS 7.8 (HIGH). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario An attacker could exploit this vulnerability to local privlidge escalation from the `monitor` user to root.
Remediation Monitor vendor advisories for a patch. Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: Identify all IDC SFX2100 devices in your environment and restrict local access to the monitor user account through network segmentation and physical access controls. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-29124 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy