CVE-2026-29124

HIGH
2026-03-05 b7efe717-a805-47cf-8e9a-921fca0ce0ce
7.8
CVSS 3.1
Share

CVSS Vector

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 12, 2026 - 22:06 vuln.today
PoC Detected
Mar 11, 2026 - 18:35 vuln.today
Public exploit code
CVE Published
Mar 05, 2026 - 02:16 nvd
HIGH 7.8

Description

Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the `monitor` user to root

Analysis

Sfx2100 Satellite Receiver firmware contains multiple SUID root binaries in predictable locations that allow local privilege escalation from the monitor user to root. Public exploit code exists for this vulnerability, enabling any local user with monitor privileges to gain complete system control. …

Sign in for full analysis, threat intelligence, and remediation guidance.

Remediation

Within 24 hours: Identify all IDC SFX2100 devices in your environment and restrict local access to the `monitor` user account through network segmentation and physical access controls. Within 7 days: Implement file permission audits on affected binaries and remove SUID bits where operationally feasible; isolate affected systems from critical networks. …

Sign in for detailed remediation steps.

Priority Score

59
Low Medium High Critical
KEV: 0
EPSS: +0.0
CVSS: +39
POC: +20

Share

CVE-2026-29124 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy