Skip to main content

Hg9 Firmware CVE-2026-2910

HIGH
Buffer Overflow (CWE-119)
2026-02-22 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate as valid user
  2. Delivery
    Send crafted POST to /boaform/formPing6
  3. Exploit
    Inject oversized pingAddr parameter
  4. Execution
    Overflow stack buffer
  5. Impact
    Execute arbitrary code with router privileges

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Tenda HG9 (firmware 300001138) with /boaform/formPing6 endpoint accessible. Valid credentials required for authentication. Stack-based buffer overflow via pingAddr parameter manipulation during ping6 form processing.

Impact

CVSS 8.8 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network. Public exploit/POC available.

Exploit ScenarioDerived

A remote attacker could exploit this vulnerability to stack-based buffer overflow.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Stack-based buffer overflow in Tenda HG9 firmware's pingAddr parameter allows unauthenticated remote attackers to achieve code execution through the /boaform/formPing6 endpoint. Public exploit code exists for this vulnerability, and no patch is currently available. The flaw carries high severity with complete compromise potential across confidentiality, integrity, and availability.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 22:04 CVSS 8.8

A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. [CVSS 8.8 HIGH]

RemediationAI

Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-119 (Buffer Overflow). Affects Hg9 Firmware. A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.

Know when Hg9 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Feb 23, 2026 - 20:21 vuln.today
Public exploit code
CVE Published
Feb 22, 2026 - 04:15 nvd
HIGH 8.8

DescriptionCVE.org

A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.

Executive ViewAI

Why It Matters

A high-severity vulnerability (CVSS 8.8) has been discovered in Tenda HG9 devices that could allow attackers to compromise affected network equipment. Organizations using this router model face immediate risk of unauthorized access and network infiltration, with public exploits already available. Immediate action is required to identify affected devices and implement protective measures until a vendor patch is released.

Business Impact: High
Compensating Controls

Disable remote access and web-based management interfaces on affected Tenda HG9 devices. Implement network segmentation and restrict administrative access via firewall rules to trusted networks only. Deploy intrusion detection/prevention signatures targeting /boaform/formPing6 exploitation attempts. Configure WAF rules to block suspicious IPv6 ping requests if accessible from untrusted networks. Disable IPv6 functionality if not required. Monitor device logs for unauthorized access attempts. Consider temporary replacement or bypass of affected devices until vendor patch is available.

Threat Intelligence Overview

EPSS Score
0.1%
Top 76% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:hg9_firmware:300001138:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy