Skip to main content

W30e Firmware CVE-2026-24440

HIGH
Unverified Password Change (CWE-620)
2026-01-26 disclosure@vulncheck.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Analysis Generated
Mar 12, 2026 - 22:00 vuln.today
CVE Published
Jan 26, 2026 - 18:16 nvd
HIGH 8.8

DescriptionCVE.org

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.

AnalysisAI

Unauthenticated password modification in Tenda W30E V2 firmware through the maintenance interface allows authenticated users to reset account credentials without password verification, potentially enabling privilege escalation or account takeover on affected devices. The vulnerability affects firmware versions up to V16.01.0.19(5037) and currently lacks an available patch.

Technical ContextAI

Affects the maintenance component of W30E Firmware. Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.

RemediationAI

Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.

CVE-2024-32286 CRITICAL POC
9.8 Apr 17

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVir

CVE-2023-49411 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode. Rated critical

CVE-2023-49406 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet

CVE-2023-49405 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg. Rated critical sever

CVE-2023-49404 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Rated c

CVE-2023-50002 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode. Rated criti

CVE-2023-50001 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline. Rated cr

CVE-2023-50000 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode. Rated critic

CVE-2023-49999 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPa

CVE-2023-49410 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status

CVE-2023-49403 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools. R

CVE-2023-49402 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg. Rated critical severi

Share

CVE-2026-24440 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy