Skip to main content

W30e Firmware CVE-2026-24433

MEDIUM
Cross-site Scripting (XSS) (CWE-79)
2026-01-26 disclosure@vulncheck.com
5.4
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Output encoding, context-aware escaping
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 5.4 (MEDIUM). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: Required. Exploitation requires authentication.

Exploit ScenarioDerived

An attacker (requires authentication) could exploit this vulnerability to compromise the affected system.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Tenda W30E V2 firmware through V16.01.0.19(5037) fails to properly sanitize user input during account creation, allowing authenticated attackers to inject persistent malicious scripts that execute in administrators' browsers when accessing management pages. This stored XSS vulnerability enables session hijacking, credential theft, and unauthorized configuration changes with low complexity exploitation requiring only user interaction from an admin. No patch is currently available for affected devices.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 22:00 CVSS 5.4

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. [CVSS 5.4 MEDIUM]

RemediationAI

Monitor vendor advisories for a patch. Implement output encoding and Content Security Policy headers. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-79 (Cross-site Scripting (XSS)). Affects the user creation component of W30E Firmware. Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages.

Know when W30e Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.4 MEDIUM
AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

DescriptionCVE.org

Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages.

Executive ViewAI

Why It Matters

CVE-2026-24433 presents moderate security risk, a cross-site scripting vulnerability rated CVSS 5.4. Attackers could inject scripts to steal sessions or perform actions as authenticated users. Organizations should apply vendor updates when available and monitor for exploitation.

Business Impact: Low
Compensating Controls

Apply vendor patch. If patching is delayed: implement CSP headers, enable HttpOnly cookies, deploy WAF XSS rules.

Threat Intelligence Overview

EPSS Score
0.0%
Top 99% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Low

Priority Score

27
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +27
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Cross-Site Scripting occurs when an application accepts untrusted data and sends it to a web browser without proper validation or encoding.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:w30e_firmware:*:*:*:*:*:*:*:*
CVE-2024-32286 CRITICAL POC
9.8 Apr 17

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVir

CVE-2023-49411 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode. Rated critical

CVE-2023-49406 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet

CVE-2023-49405 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg. Rated critical sever

CVE-2023-49404 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Rated c

CVE-2023-50002 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode. Rated criti

CVE-2023-50001 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline. Rated cr

CVE-2023-50000 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode. Rated critic

CVE-2023-49999 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPa

CVE-2023-49410 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status

CVE-2023-49403 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools. R

CVE-2023-49402 CRITICAL POC
9.8 Dec 07

Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg. Rated critical severi

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy