Ac8 Firmware CVE-2026-2203

HIGH
Buffer Overflow (CWE-119)
2026-02-09 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 12, 2026 - 21:54 vuln.today
PoC Detected
Feb 10, 2026 - 15:07 vuln.today
Public exploit code
CVE Published
Feb 09, 2026 - 03:16 nvd
HIGH 8.8

DescriptionCVE.org

A flaw has been found in Tenda AC8 16.03.33.05. Affected by this vulnerability is an unknown functionality of the file /goform/fast_setting_wifi_set of the component Embedded Httpd Service. This manipulation of the argument timeZone causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

AnalysisAI

Buffer overflow in Tenda AC8 firmware version 16.03.33.05 allows authenticated remote attackers to execute arbitrary code via the timeZone parameter in the /goform/fast_setting_wifi_set endpoint. Public exploit code exists for this vulnerability, and no patch is currently available. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Authenticate to Tenda AC8 web interface
Delivery
Send crafted HTTP request to /goform/fast_setting_wifi_set
Exploit
Inject oversized timeZone parameter
Execution
Trigger buffer overflow in Embedded Httpd
Impact
Execute arbitrary code on router

Vulnerability AssessmentAI

Exploitation Tenda AC8 firmware version 16.03.33.05; requires valid login credentials to access /goform/fast_setting_wifi_set endpoint on Embedded Httpd Service; standard HTTP web interface must be enabled. Additional conditions and limiting factors are described in the full assessment.
Risk Assessment CVSS 8.8 (HIGH). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario A remote attacker could exploit this vulnerability to compromise the affected system.
Remediation Monitor vendor advisories for a patch. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: Inventory all Tenda AC8 devices in production and isolate affected units from critical network segments. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

CVE-2026-2203 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy