Br 6208ac Firmware
CVE-2026-1972
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Default credential prevention
|
| Impact | CVSS 5.3 (MEDIUM). Attack vector: Network. Complexity: Low. Privileges required: None. User interaction: None. Exploitable via remote/network. Public exploit/POC available. |
| Exploit ScenarioDerived | A remote attacker could exploit this flaw, use of default credentials. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 12, 2026
Edimax BR-6208AC firmware versions prior to 2_1.02 contain an authentication bypass in the auth_check_userpass2 function that allows remote attackers to gain access using default credentials through manipulation of username and password parameters. Public exploit code exists for this vulnerability, and the affected product is end-of-life with no vendor patches planned. Organizations still operating this router should immediately restrict network access or plan for replacement.
Earlier versions of this analysis (1)
A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. [CVSS 5.3 MEDIUM]
RemediationAI
Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Affects Br-6208Ac Firmware. A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects pr
Know when Br 6208ac Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability was found in Edimax BR-6208AC 2_1.02. The affected element is the function auth_check_userpass2. Performing a manipulation of the argument Username/Password results in use of default credentials. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor confirms that the affected product is end-of-life. They confirm that they "will issue a consolidated Security Advisory on our official support website." This vulnerability only affects products that are no longer supported by the maintainer.
Executive ViewAI
Organizations using A vulnerability should be aware of moderate risk from CVE-2026-1972 rated CVSS 5.3. Exploitation could compromise the security of affected deployments. Proof-of-concept code is publicly available. Organizations should apply vendor updates when available and monitor for exploitation.
Apply vendor patch. If patching is delayed: restrict network access and enable monitoring.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Br 6208ac Firmware
View allEDIMAX BR-6208AC V2 router allows command injection through the pppUserName field via system() without sanitization. PoC
Command injection in the Edimax BR-6208AC V2 web-based configuration interface exposes unauthenticated remote attackers
Command injection in the Edimax BR-6208AC V2 web-based configuration interface (firmware 1.02 and 1.03) allows remote at
Path traversal in the FTP daemon service of Edimax BR-6208AC firmware version 1.02 allows authenticated remote attackers
Open redirect vulnerability in Edimax BR-6208AC firmware versions 1.02 and 1.03 allows authenticated remote attackers to
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB