Skip to main content

Tenda CVE-2026-1689

MEDIUM
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2026-01-30 cna@vuldb.com
5.5
CVSS 4.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Send crafted Host header to /boaform/admin/formLogin
  2. Exploit
    Bypass checkUserFromLanOrWan validation
  3. Execution
    Inject OS commands in Host parameter
  4. Impact
    Execute arbitrary commands on router

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Input neutralization, injection prevention
Exploitation Conditions

Tenda HG10 device with firmware version US_HG7_HG9_HG10re_300001138_en_xpon; /boaform/admin/formLogin endpoint accessible without authentication; no special network conditions required for remote exploitation

Impact

CVSS 7.3 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: None. User interaction: None. Exploitation requires authentication. Exploitable via remote/network. Public exploit/POC available.

Exploit ScenarioDerived

A remote attacker (requires authentication) could exploit this flaw, command injection.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 4.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Command injection in Tenda HG10 firmware's login interface allows unauthenticated remote attackers to execute arbitrary commands by manipulating the Host parameter in the checkUserFromLanOrWan function. Public exploit code exists for this vulnerability, and no patch is currently available. The attack requires no user interaction and can fully compromise affected devices through remote code execution.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 22:00 CVSS 7.3

A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. [CVSS 7.3 HIGH]

RemediationAI

Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Affects the of the component of Hg10 Firmware. A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.

Know when Tenda gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.5 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
Low
Vulnerable system: Availability
Low
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

4
Severity Changed
Apr 29, 2026 - 01:11 NVD
HIGH MEDIUM
CVSS changed
Apr 29, 2026 - 01:11 NVD
7.3 (HIGH) 5.5 (MEDIUM)
PoC Detected
Feb 10, 2026 - 14:18 vuln.today
Public exploit code
CVE Published
Jan 30, 2026 - 17:16 nvd
HIGH 7.3

DescriptionCVE.org

A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.

Executive ViewAI

Why It Matters

A HIGH severity authentication bypass vulnerability exists in Tenda HG10 routers that could allow attackers to gain unauthorized administrative access to network infrastructure. Organizations using this device model face immediate risk of network compromise, data theft, and service disruption, with no vendor patch currently available.

Business Impact: High
Compensating Controls

Disable remote WAN access to the login interface; restrict LAN access to the admin interface via firewall rules to trusted IPs only; implement network segmentation to isolate affected routers from sensitive systems; enable IP-based access control lists; consider deploying a WAF or reverse proxy in front of the device to monitor and block suspicious authentication attempts; monitor logs for brute force attacks on the /boaform/admin/formLogin endpoint; enforce strong password policies; consider disabling the device until replacement is feasible if it controls access to critical infrastructure.

Threat Intelligence Overview

EPSS Score
4.5%
Top 11% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC Yes
EPSS 4.5%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

53
Low Medium High Critical
KEV: 0
EPSS: +5
CVSS: +28
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:hg10_firmware:-:*:*:*:*:*:*:*

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy