Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent-network access to charger
-
DeliveryReach OCPP backend config interface
-
ExploitAuthenticate with hard-coded credentials
-
ExecutionBypass authentication control
-
PersistChain with secondary flaw
-
ImpactExecute arbitrary code on device
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Credential externalization
MITRE ATT&CK
2 techniques across 2 tactics: Persistence, Credential Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires network adjacency (AV:A): the attacker must be on the same local or link-layer network as the Grizzl-E Smart 40A charger - it is not exploitable from the internet without first reaching that network segment. No authentication is required (PR:N) and no user interaction is needed (UI:N); the specific prerequisite is reaching the OCPP backend settings configuration interface, where the use of hard-coded credentials allows the authentication bypass. The key limiting factor beyond adjacency is that, by the advisory's own wording, achieving arbitrary code execution requires chaining this bypass with other, separate vulnerabilities - the hard-coded-credential flaw alone yields unauthorized access to backend configuration, not standalone RCE. |
| Impact | This is a moderate-priority issue whose real-world risk is tempered by its attack vector. The CVSS 3.0 base score is 7.6 with vector AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L - the critical limiter is AV:A (adjacent network), meaning an attacker must already be on the same local/link-layer network as the charger (e.g., the same Wi-Fi or LAN segment), not the open internet. PR:N confirms no authentication is required once adjacency is achieved, and AC:L means no special conditions beyond that. The vuln.today Decision label is 'this_week', consistent with a serious-but-not-emergency item. No EPSS score, no CISA KEV listing, and no confirmed public exploit code were provided in the input, so there is no public exploit identified at time of analysis and no evidence of active exploitation - the signals are not conflicting, they are simply incomplete on the exploitation-likelihood side. Note the input tags this as 'RCE', but per the description code execution is only achievable 'in conjunction with other vulnerabilities'; on its own this flaw is an authentication bypass via hard-coded credentials (CWE-798), so treating it as standalone RCE would overstate impact. Overall: a genuine authentication-bypass weakness worth patching promptly, but the adjacent-network requirement and absence of exploitation signals place it below internet-facing critical flaws in triage. |
| Exploit ScenarioDerived | An attacker who has gained a foothold on the same local network as a Grizzl-E Smart 40A charger (for example via the home/site Wi-Fi) connects to the OCPP backend configuration interface and authenticates using the device's hard-coded credentials, bypassing authentication entirely. Having taken control of the backend configuration, the attacker chains this access with other device weaknesses to achieve arbitrary code execution in the context of the device. No public exploit was identified at time of analysis, and the chaining requirement means this is not a single-shot remote compromise. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Nov 19, 2026
Authentication bypass in United Chargers Grizzl-E Smart 40A EV chargers lets network-adjacent attackers reach the OCPP backend settings interface using hard-coded credentials, with no authentication or user interaction required (CVSS 7.6). The flaw (CWE-798) yields unauthorized access to backend configuration; per the advisory, arbitrary code execution on the device is only achievable by chaining this bypass with other, separate vulnerabilities, so the bypass on its own is not standalone RCE. No public exploit code and no CISA KEV entry are associated with this CVE in the available data, and exploitation is limited to attackers already positioned on the same local or link-layer network segment as the charger.
RemediationAI
No vendor-released patch or fixed firmware version is identified in the available data, so remediation must begin with confirming status directly with United Chargers and monitoring the ZDI advisory ZDI-26-1032 (https://www.zerodayinitiative.com/advisories/ZDI-26-1032/) for a firmware update. Until a fix is published, the most effective compensating control is to place Grizzl-E Smart 40A chargers on a dedicated network segment or VLAN that is isolated from user devices and the internet, accepting the operational trade-off that remote management and OCPP connectivity must then be brokered through a controlled gateway. Restrict access to the OCPP backend settings interface to a small set of trusted management hosts via firewall rules, recognizing that this constrains legitimate commissioning and maintenance workflows, and filter charger egress so OCPP traffic reaches only the intended central management system, with the caveat that overly strict filtering can break legitimate backend roaming or firmware updates. Monitor charger configuration for unauthorized changes and watch for anomalous connections to the settings interface, since detection of the bypass depends on logging that the device may not expose by default.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected component is the charger's OCPP (Open Charge Point Protocol) backend settings interface, which stores the configuration a charging station uses to connect to its central management system. The root cause is CWE-798, use of hard-coded credentials: a static username/password pair embedded in the device configuration is used to authenticate access to that settings interface, so anyone who knows or extracts the value can authenticate without a per-device secret. The assessed vector (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L) reflects that the attacker must be network-adjacent to the charger rather than internet-facing, needs no credentials (PR:N) and no user interaction (UI:N), and that the dominant impact is to integrity of the backend configuration, with limited confidentiality and availability impact. The advisory's RCE tag reflects a chained scenario; the trigger path for code execution beyond the credential bypass is not described in the available sources. No CPE identifiers or explicit firmware version ranges were supplied in the intelligence data, so the precise set of affected firmware builds is unverified beyond the named product.
Know when the next one hits your stack
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L
Adjacent network and no auth per hard-coded-credential bypass over local OCPP interface (AV:A/PR:N/AC:L); high integrity from config control, low confidentiality/availability, unchanged scope.
Primary rating from Vendor (trendmicro).
CVSS VectorVendor: trendmicro
DescriptionCVE.org
United Chargers Grizzl-E Smart 40A OCPP Backend Configuration Hard-Coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of United Chargers Grizzl-E Smart 40A EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the OCPP backend settings interface. The issue results from the use of hard-coded credentials. An attacker can leverage this vulnerability in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-29056.
Executive ViewAI
CVE-2026-131811 is an authentication bypass in United Chargers Grizzl-E Smart 40A EV chargers that allows an attacker on the same local network segment to access the OCPP backend configuration interface using hard-coded credentials. While this flaw alone does not permit remote code execution, it exposes critical backend settings and can be chained with other vulnerabilities to achieve full device compromise. Organizations with these chargers deployed in shared or untrusted network environments should treat this as a high-priority risk to operational technology and potential lateral movement.
No vendor-released patch identified at time of analysis. Interim mitigations include network segmentation to isolate chargers from untrusted networks, restriction of access to the OCPP interface to authorized IP ranges, and monitoring for unauthorized configuration changes.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
EUVD-2026-130364
GHSA-2cv3-c95r-v75j
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB