CVE-2025-8907

HIGH
2025-08-13 [email protected]
7.3
CVSS 4.0
Share

CVSS Vector

CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
High
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:06 vuln.today
CVE Published
Aug 13, 2025 - 13:15 nvd
HIGH 7.3

Description

A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.

Analysis

A vulnerability was found in H3C M2 NAS V100R006. Rated high severity (CVSS 7.3). No vendor patch available.

Technical Context

This vulnerability is classified under CWE-250. A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.

Affected Products

H3C M2 NAS V100R006. Affected by this vulnerability.

Remediation

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Priority Score

37
Low Medium High Critical
KEV: 0
EPSS: +0.0
CVSS: +36
POC: 0

Share

CVE-2025-8907 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy